| 数据搜索系统,热门电子元器件搜索 |
|
MAX1153 数据表(PDF) 19 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1153 数据表(HTML) 19 Page - Maxim Integrated Products |
|
19 / 30 page ![]() Stand-Alone, 10-Channel, 10-Bit System Monitors with Internal Temperature Sensor and VDD Monitor ___________________________________________________ 19 Setup Register The 8-bit setup register (Table 7) holds configuration data common to all input channels. At power-up and after a RESET command, this register defaults to 00000000b. Setup Register: Sample Wait Bits (B7, B6, B5) These 3 bits in the setup register (Table 8) set the wait time between conversion scans. The following are examples of how the MAX1153/MAX1154 begin a sam- ple sequence (see the Setup Register: Reference Selection Bits (B1/B0) section). Operating in reference mode 00 (external reference for voltage conversions, internal reference for temperature conversions): 1) Convert the first-enabled channel. If this channel is a temperature measurement, power up the internal reference (this takes 20µs for each enabled tem- perature measurement in reference mode 00). 2) Sequence to the next-enabled channel until all channels have been converted. 3) Wait the sample wait period. 4) Repeat the procedure. Operating in reference mode 01 (internal reference for all conversions, can be powered down between scans): 1) Power up the internal reference, if powered down (this takes 40µs). 2) Convert the first-enabled channel, starting with the internal temperature sensor, if enabled. 3) Sequence to the next-enabled channel until all enabled channels have been converted. 4) Wait the sample wait time, and enter internal refer- ence power-down mode if this period is greater than 80µs. 5) Repeat the above steps. Operating in reference mode 10 (internal reference for all conversions, continuously powered up): 1) Convert the first-enabled channel. 2) Sequence to the next-enabled channel until all enabled channels have been converted. 3) Wait the sample wait time. 4) Repeat the procedure. Use the sample wait feature to reduce supply current when measuring slow-changing analog signals. This power savings occurs when reference mode 00 or 01 is used in combination with wait times longer than 80µs. With reference mode 10 or wait times of less than 80µs, the internal reference system remains powered up, mini- mizing any power savings. See the Computing Data Throughput section. Table 8 shows the B7, B6, B5 wait time encoding. Setup Register: Interrupt Control (B4, B3) Bits B3 and B4 in the setup register configure INT and how it responds to an alarm event (see the Alarm Register section). Table 9 shows the available INT options. Table 7. Setup Register Format B7 (MSB) B6 B5 B4 B3 B2 B1 B0 (LSB) Sample wait bits Interrupt active Interrupt polarity Scan mode Reference source B1 Reference source B2 Table 8. Wait Time Encoding B7, B6, B5 WAIT TIME (ms) 000 0 001 0.080 010 0.395 011 1.310 100 4.970 101 19.600 110 78.200 111 312.000 Table 9. Interrupt Control BIT FUNCTION BIT STATE INT OPERATION 1 Driven high or low at all times B4 Output driver type 0 High-Z when inactive, driven (high or low) when active 1Active high, inactive = low or high -Z B3 Output polarity 0Active low, inactive = high or high -Z |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |