| 数据搜索系统,热门电子元器件搜索 |
|
TNETA1500APCM 数据表(PDF) 7 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETA1500APCM 数据表(HTML) 7 Page - Texas Instruments |
|
7 / 10 page ![]() TNETA1500A 155.52-MBIT/S SONET/SDH ATM RECEIVER/TRANSMITTER SDNS042A – AUGUST 1997 – REVISED JANUARY 1998 7 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 receive operation (continued) The TNETA1500A provides loss-of-signal (LOS), out-of-frame (OOF), and loss-of-frame (LOF) alarms in accordance with BellCore specification TR-NWT-000253, Issue 2, December 1991. The LOS alarm goes active when no transitions are detected on the receive serial data for 3.3 µs. The LOS alarm goes inactive when two consecutive framing patterns have been detected, and during the intervening time (one frame time), no transitionless 3.3- µs period is detected. The OOF alarm goes active when four consecutive-errored framing patterns are received. The OOF alarm clears when two successive error-free framing patterns are received. If the OOF condition fails to clear within 3 ms, the LOF alarm goes active. The LOF alarm goes inactive when eight consecutive error-free SONET frames are identified. The LOS, OOF, and LOF alarms are indicated by external signals and by setting a bit in the interrupt registers. This causes INTR of the controller interface to go active low, signaling an interrupt. After the SONET frame is established and the serial data converted to byte-wide data, the B1 BIP-8 parity is calculated over the scrambled SONET frame. This value is compared with the value of B1 contained in the next (n + 1) frame. The value of B1 calculated over the previous frame (n – 1) is compared to the value B1 in this frame (frame n). If the two values do not match, B1ERR goes active, denoting that a B1 parity error has occurred. In addition, the B1 parity-error bit in the interrupt register is set and INTR goes active low. Next, the SONET frame is unscrambled (except for the A1, A2, and C1 bytes, which were not scrambled by the transmitter). The B2 BIP-24 value is calculated over all the bits of the line overhead and the STS-3c envelope capacity and compared to the value contained in the next frame. If a B2 parity error occurs, the B2 parity-error bit in the interrupt register is set and INTR goes active low to notify the controller that a parity error has occurred. The TNETA1500A monitors the receive K2 byte for line alarm-indication signal (LAIS) and line far-end receive failure (LFERF) alarms. A LAIS alarm occurs when bits 6–8 of the receive K2 byte are set to a value of 111 for five consecutive frames. The LAIS alarm goes inactive when bits 6–8 of the receive K2 byte are set to any value other than 111 for five consecutive frames. The LFERF alarm goes active when bits 6–8 of the receive K2 byte are set to a value of 110 for five consecutive frames. The LFERF alarm goes inactive when bits 6–8 of the receive K2 byte are set to any value other than 110 for five consecutive frames. Both the LAIS and LFERF alarms are indicated on an external terminal and by setting a bit in interrupt register 2. The location of the J1 byte in the SPE is determined from the H1 and H2 bytes in the TOH. The location of the J1 byte does not change from the previous frame unless the first four bits of H1 are set to 1001 (the new-data flag) or the pointer value contained in H1 and H2 is different for three consecutive frames. The location of J1 also can be incremented or decremented by a 1-byte position by inverting certain bits in the H1 and H2 byte pointer. If bits 7, 9, 11, 13, and 15 are inverted, the location of J1 is incremented one time slot. If bits 8, 10, 12, 14, and 16 are inverted, the location of J1 is decremented one time slot. Subsequent pointers contain the new offset. The TNETA1500A provides a loss-of-pointer (LOP) alarm to indicate that either an invalid pointer was detected in the incoming H1 and H2 bytes or a new-data flag (NDF) (set to a value of 1001 — the first four bits of H1) was found in eight consecutive frames. The LOP alarm goes inactive when a valid pointer with the NDF set to 0110 is detected in three consecutive frames. The device also provides a path-AIS alarm to indicate that a path-AIS condition has been detected in the H1 and H2 bytes. A path-AIS condition is detected as an all-1s condition in bytes H1 and H2 for three consecutive frames. The path-AIS alarm goes inactive when a valid pointer, with the NDF set to 0110, is detected for three consecutive frames. The LOP alarm is not set if a path-AIS condition is detected. The LOP alarm is indicated by an external signal and by the interrupt register. The path-AIS alarm is indicated only by the interrupt register. The B3 BIP-8 byte is calculated over the contents of the STS-3c SPE, which begins with the J1 byte. The value calculated for B3 is compared with the value found in the next frame. If a B3 parity error occurs, the B3 parity-error bit is set in the interrupt register and INTR goes active low to notify the controller. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |