| 数据搜索系统,热门电子元器件搜索 |
|
SMB117 数据表(PDF) 17 Page - Summit Microelectronics, Inc. |
|
|
|||||||||||||||||||||||||||||
SMB117 数据表(HTML) 17 Page - Summit Microelectronics, Inc. |
|
17 / 32 page ![]() SMB113A/B/SMB117/A Preliminary Information Summit Microelectronics, Inc 2111 2.6 9/16/2010 17 APPLICATIONS INFORMATION (CONTINUED) MANUAL MODE The SMB113A/B and SMB117/A provide a manual power-on mode in which each channel may be enabled individually irrespective of the state of other channels. In this mode, the enable signal has complete control over the channel, and all sequencing is ignored. In Manual mode, channels will not be disabled in the event of a UV/OV fault on any output or the VBATT pin. FORCE-SHUTDOWN When a battery fault occurs, a UV/OV is detected on any output, or an I 2C force-shutdown command is issued, all channels will be immediately disabled, ignoring sequence positions or power off delay times. SEQUENCE TERMINATION TIMER At the beginning of each sequence position, an internal programmable timer will begin to time out. When this timer has expired, the SMB113A/B and SMB117/A will automatically perform a force-shutdown operation. This timer is user programmable with a programmable sequence termination period (tPST) of 50, 100, 200 ms; this function can also be disabled. POWER OFF SEQUENCING The SMB113A/B and SMB117/A have a power-off sequencing operation. During a power off operation, the supplies will be powered off in the reverse order they where powered on in. During the power off sequencing, all enables are ignored. When a power-off command is issued the SMB113A/B and SMB117/A will set the sequence position counter to the last sequence position and disable that channel without soft-start control; once off, the power off delay for the channel(s) in the next to last sequence position will begin to timeout, after which that channel(s) will be disabled. This process will continue until all channels have been disabled and are off. The programmable If a channel fails to turn off within the sequence termination period, the sequence termination timer will initiate a force shutdown, if enabled. INPUT AND OUTPUT MONITORING Both products monitor all outputs for under-voltage (UV) and over-voltage (OV) faults. The monitored levels are user programmable, and may be set at 5, 10, 15, and 20 percent of the nominal output voltage. The VBATT pin is monitored for two user programmable UV settings. The VBATT UV settings are programmable from 2.55V to 3.45V in 150mV increments. Once the UV/OV voltage set points have been violated, the SMB113A/B and SMB117/A can be programmed to respond in one of three ways, perform: a power-off operation, a force-shutdown operation and-or it can trigger the nRESET/HEALTHY pin. SOFT START The SMB113A/B and SMB117/A provide a programmable soft-start function for all PWM outputs. The soft-start control limits the slew rate that each output is allowed to ramp up without the need for an external capacitor. The soft start slew rate is proportional to the product of the output voltage and a slew rate reference. This global reference is programmable and may be set to 400, 200, 100, 67, 50, 33, 25, and 20 Volts per second. The slew rate control can also be disabled on any channel not requiring the feature. DYNAMIC VOLTAGE MANAGEMENT The SMB113A/B/117/A have two additional voltage settings, dynamic voltage control high and low settings. Together with the nominal voltage setting, three pre-determined voltage levels can be used. The three voltage levels are ideal for situations where a core voltage needs to be reduced for power conservation. The dynamic voltage control high and low settings have the same voltage range as the controllers’ nominal output voltage. These settings are stored in the non-volatile configuration registers and can be set by a write to volatile configuration registers. The dynamic voltage control command registers contain two bits for each channel that adjust the output voltages to the high, low or nominal set point after a volatile I2C write command. A seven level dynamic voltage control option is available for channel 3. When enabled, seven level dynamic voltage control allows channel 3 to be dynamically modified to one of seven pre-determined voltage levels. This transition is made by means of a volatile I 2C write command. When all channels are at their voltage setting, a bit is set in the dynamic voltage control status registers. + – VREF R1 R2 COMP1 Vout Vout= Vref* (1 + R2/R1) Soft-Start Slew Rate=SRref* (1 + R2/R1) Figure 6 – The output voltage is set by the voltage divider . The VREF voltage is programmable from 0 to 1.0 volt in 4mV increments via the I 2C interface |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |