46 / 60 page ![]() ADE7753 Rev. C | Page 46 of 60 Apparent Energy Voltage rms compensation is done after the LPF3 filter (see Figure 56). Apparent energy gain calibration is provided for both meter-to- meter gain adjustment and for setting the VAh/LSB constant. VRMS = VRMS0 + VRMSOS (64) VAENERGY = ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ + × × 12 2 1 1 VAGAIN VADIV VAENERGY initial (68) where: VRMS0 is the rms measurement without offset correction. VRMS is linear from full-scale to full-scale/20. VADIV is similar to the CFDEN for the watt hour calibration. It should be the same across all meters and determines the VAh/LSB constant. VAGAIN is used to calibrate individual meters. To calibrate the offset, two VRMS measurements are required, for example, at Vnominal and Vnominal/10. Vnominal is set at half of the full-scale analog input range so the smallest linear VRMS reading is at Vnominal/10. VRMSOS = 1 2 1 2 2 1 V V VRMS V VRMS V − × − × (65) Apparent energy gain calibration should be performed before rms offset correction to make most efficient use of the current test points. Apparent energy gain and watt gain compensation require testing at Ib while rms and watt offset correction require a lower test current. Apparent energy gain calibration can be done at the same time as the watt-hour gain calibration using line cycle accumulation. In this case, LAENERGY and LVAENERGY, the line cycle accumulation apparent energy register, are both read following the line cycle accumulation interrupt. Figure 87 shows a flowchart for calibrating active and apparent energy simultaneously. where VRMS1 and VRMS2 are rms register values without offset correction for input V1 and V2, respectively. If the range of the 12-bit, twos complement VRMSOS register is not enough, the voltage channel offset register, CH2OS, can be used to correct the VRMS offset. Current rms compensation is performed before the square root: IRMS2 = IRMS02 + 32768 × IRMSOS (66) VAGAIN = INT ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ × ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ − 12 ) ( ) ( 2 1 nominal IB expected IB LVAENERGY LVAENERGY (69) where IRMS0 is the rms measurement without offset correction. The current rms calculation is linear from full-scale to full- scale/100. LVAENERGYIB(expected) = INT ⎟ ⎟ ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎜ ⎜ ⎝ ⎛ × × × (s) s/h 3600 time on Accumulati constant LSB VAh I V B nominal (70) To calibrate this offset, two IRMS measurements are required, for example, at Ib and IMAX/50. IMAX is set at half of the full-scale analog input range so the smallest linear IRMS reading is at IMAX/50. IRMSOS = 2 1 2 2 2 1 2 2 2 2 2 1 I I IRMS I IRMS I − × − × × 32768 1 (67) The accumulation time is determined from Equation 37 and the line period can be determined from the PERIOD register accord- ing to Equation 38. The VAh represented by the VAENERGY register is where IRMS1 and IRMS2 are rms register values without offset correction for input I1 and I2, respectively. VAh = VAENERGY × VAh/LSB constant (71) The VAh/LSB constant can be verified using this equation: LVAENERGY time on Accumulati VA constant LSB VAh 3600 (s) × = (72) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |