| 数据搜索系统,热门电子元器件搜索 |
|
AR1010T-I/ML 数据表(PDF) 45 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
AR1010T-I/ML 数据表(HTML) 45 Page - Microchip Technology |
|
45 / 70 page ![]() 2009-2012 Microchip Technology Inc. Preliminary DS41393B-page 45 AR1000 SERIES RESISTIVE TOUCH SCREEN CONTROLLER 10.0 APPLICATION NOTES 10.1 Calibration of Touch Sensor with Controller The reported coordinates from a touch screen controller are typically calibrated to the application’s video display. The task is often left up to the host to perform. This controller provides a feature for it to send coordinates that have already been calibrated, rather than the host needing to perform this task. If enabled, the feature will apply pre-collected 4-point calibration data to the reported touch coordinates. Calibration only accounts for X and Y directional scaling. It does not correct for angular errors due to rotation of the touch sensor on the video display. The calibration process can be cancelled at anytime by sending a command to the controller. Upon completion of the calibration process, the calibration data is automatically stored to the EEPROM and “Calibrated Coordinates” is enabled. The process of “calibration” with the controller is described below. 1. Disable touch reporting by issuing <Disable Touch> command. Send: <0x55><0x01><0x13> Receive: <0x55><0x02><Response><0x13> 2. Get register group Start address by issuing REGISTER_START_ADDRESS_REQUEST command. A register Start address of 0x20 is used below, for this example. Send: <0x55><0x01><0x22> Receive: <0x55><0x03><0x00><0x22><0x20> 3. Calculate the CalibrationInset register’s address by adding its offset value of 0x0E to the register group Start address of 0x20. Register Address = Register Start Address + CalibratioInset Register Offset = 0x20 + 0x0E = 0x2E 4. Calculate the desired value for the CalibrationIn- set register. A Calibration Inset of 12.5% is used below for this example. CalibrationInset = 2 * Desire Calibration Inset % = 2 * 12.5 = 25 = 0x19 5. Set the Calibration Inset by writing the desired value to the CalibrationInset register. Send:<0x55><0x05><0x21><0x00><0x2E><0x01 ><0x19> Receive: <0x55><0x02><0x00><0x21> 6. Issue the CALIBRATE_MODE command. Send: <0x55><0x02><0x14><0x04> Receive: <0x55><0x02><0x00><0x14> 7. Software must display the first calibration point target in the upper left quadrant of the display and prompt the user to touch and release the target. FIGURE 10-1: SUGGESTED TEXT FOR FIRST CALIBRATION TARGET 8. Wait for the user to touch and release the first calibration point target. Do this by looking for a controller response of: <0x55><0x02><0x00> <0x14> 9. Software must display the second calibration point target in the upper right quadrant of the display and prompt the user to touch and release the target. FIGURE 10-2: SUGGESTED TEXT FOR SECOND CALIBRATION TARGET 10. Wait for the user to touch and release the second calibration point target. Do this by looking for a controller response of: <0x55><0x02><0x00><0x14> Touch and Release Target Touch and Release Target |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |