| 数据搜索系统,热门电子元器件搜索 |
|
COMBOSMARTMETER 数据表(PDF) 16 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
COMBOSMARTMETER 数据表(HTML) 16 Page - Texas Instruments |
|
16 / 60 page ![]() 2x 1x 1x 8x AVDD AVSS Temperature Sensor Monitor To MUX TempP To MUX TempN Temperature ( C) = ° Temperature Reading ( V) 168,000 V m - m 394 V/ C m ° + 25 C ° ADS131E04 ADS131E06 ADS131E08 SBAS561A – JUNE 2012 – REVISED APRIL 2013 www.ti.com Device Noise Measurements Setting CHnSET[2:0] = 001 sets the common-mode voltage of [(VREFP + VREFN) / 2] to both channel inputs. This setting can be used to test inherent device noise in the user system. Test Signals (TestP and TestN) Setting CHnSET[2:0] = 101 provides internally-generated test signals for use in sub-system verification at power- up. Test signals are controlled through register settings (see the CONFIG2: Configuration Register 2 subsection in the Register Map section for details). TEST_AMP controls the signal amplitude and TEST_FREQ controls switching at the required frequency. The test signals are multiplexed and transmitted out of the device at the TESTP and TESTN pins. A bit register (CONFIG2.INT_TEST = 0) deactivates the internal test signals so that the test signal can be driven externally. This feature allows the calibration of multiple devices with the same signal. Temperature Sensor (TempP, TempN) The ADS131E0x contain an on-chip temperature sensor. This sensor uses two internal diodes with one diode having a current density 16x that of the other, as shown in Figure 18. The difference in diode current densities yields a difference in voltage that is proportional to absolute temperature. As a result of the low thermal resistance of the package to the printed circuit board (PCB), the internal device temperature tracks the PCB temperature closely. Note that self-heating of the ADS131E0x causes a higher reading than the temperature of the surrounding PCB. The scale factor of Equation 1 converts the temperature reading to °C. Before using this equation, the temperature reading code must first be scaled to μV. (1) Figure 18. Temperature Sensor Measurement in the Input Supply Measurements (MVDDP, MVDDN) Setting CHnSET[2:0] = 011 sets the channel inputs to different device supply voltages. For channels 1, 2, 5, 6, 7, and 8, (MVDDP – MVDDN) is [0.5(AVDD – AVSS)]; for channels 3 and 4, (MVDDP – MVDDN) is DVDD / 4. Note that to avoid saturating the PGA while measuring power supplies, the gain must be set to '1'. 16 Submit Documentation Feedback Copyright © 2012–2013, Texas Instruments Incorporated Product Folder Links: ADS131E04 ADS131E06 ADS131E08 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |