34 / 48 page ![]() ADM1275 Data Sheet Rev. D | Page 34 of 48 ADM1275 ALERT PIN BEHAVIOR The ADM1275 provides a very flexible alert system, whereby one or more fault/warning conditions can be indicated to an external device. FAULTS AND WARNINGS A PMBus fault on the ADM1275 is always generated due to an analog event and causes a change in state in the hot-swap output, turning it off. The three defined fault sources are as follows: • Undervoltage (UV) event detected on the UV pin • Overvoltage (OV) event detected on the OV pin • Overcurrent (OC) event that causes a hot-swap timeout Faults are continuously monitored, and, as long as power is applied to the device, they cannot be disabled. When a fault occurs, a corresponding status bit is set in one or more STATUS_xxx registers. A value of 1 in a status register bit field always indicates a fault or warning condition. Fault and warning bits in the status registers are latched when set to 1. To clear a latched bit to 0— provided that the fault condition is no longer active—use the CLEAR_FAULTS command or use the OPERATION command to turn the hot-swap output off and then on again. A warning is less severe than a fault and never causes a change in the state of the hot-swap controller. The eight sources of a warning are defined as follows: • CML: a communications error occurred on the I2C bus • HS timer was active (HSTA): the current regulation was active, but does not necessarily shut the system down • IOUT OC warning from the ADC • IOUT Warning 2 from the ADC • VIN UV warning from the ADC • VIN OV warning from the ADC • VOUT UV warning from the ADC (ADM1275-1 and ADM1275-3 only) • VOUT OV warning from the ADC (ADM1275-1 and ADM1275-3 only) GENERATING AN ALERT A host device can periodically poll the ADM1275 using the status commands to determine whether a fault/warning is active. However, this polling is very inefficient in terms of software and processor resources. The ADM1275 has GPOx/ALERTx output pins that can be used to generate interrupts to a host processor. • ADM1275-1: GPO1/ALERT1/CONV and GPO2/ALERT2 • ADM1275-2: GPO1/ALERT1/CONV • ADM1275-3: GPO2/ALERT2 By default at power-up, the open-drain GPOx/ALERTx outputs are high impedance, so the pins can be pulled high through resistors. No faults or warnings are enabled on the GPO1/ ALERT1/CONV pin at power-up; the user must explicitly enable the faults or warnings to be monitored. The FET health bad warning is active by default on the GPO2/ALERT2 pin at power-up. Any one or more of the faults and warnings listed in the Faults and Warnings section can be enabled and cause an alert, making the corresponding GPOx/ALERTx pin active. By default, the active state of a GPOx/ALERTx pin is low. For example, to use GPO1/ALERT1/CONV to monitor the VOUT UV warning from the ADC, the followings steps must be performed: 1. Set a threshold level with the VOUT_UV_WARN_LIMIT command. 2. Start the power monitor sampling on VOUT. If a VOUT sample is taken that is below the configured VOUT UV value, the GPO1/ALERT1/CONV pin is taken low, signaling an interrupt to a processor. HANDLING/CLEARING AN ALERT When faults/warnings are configured on the GPOx/ALERTx pins, the pins become active to signal an interrupt to the processor. (These pins are active low, unless inversion is enabled.) The GPOx/ALERTx signal functions as an SMBAlert. Note that the GPOx/ALERTx pins can become active indepen- dently of each other, but they are always made inactive together. A processor can respond to the interrupt in one of two basic ways: • If there is only one device on the bus, the processor can simply read the status bytes and issue a CLEAR_FAULTS command to clear all the status bits, which causes the deassertion of the GPOx/ALERTx line. If there is a persistent fault—for example, an undervoltage on the input—the status bits remain set after the CLEAR_FAULTS command is executed because the fault has not been removed. However, the GPOx/ALERTx line is not pulled low unless a new fault/ warning becomes active. If the cause of the SMBAlert is a power monitor generated warning and the power monitor is running continuously, the next sample generates a new SMBAlert after the CLEAR_FAULTS command is issued. • If there are several devices on the bus, the processor can issue an SMBus alert response address command to find out which device asserted the SMBAlert line. The processor can read the status bytes from that device and issue a CLEAR_FAULTS command. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |