| 数据搜索系统,热门电子元器件搜索 |
|
ADM1275-2ARQZ-R7 数据表(PDF) 40 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1275-2ARQZ-R7 数据表(HTML) 40 Page - Analog Devices |
|
40 / 48 page ![]() ADM1275 Data Sheet Rev. D | Page 40 of 48 STATUS_INPUT Code: 0x7C, read byte. Value after reset: 0x00. Table 24. Bit Descriptions for STATUS_INPUT Command Bits Bit Name Behavior Settings Description 7 VIN_OV_FAULT Latched 0 No overvoltage detected on the OV pin. 1 An overvoltage was detected on the OV pin. 6 VIN_OV_WARN Latched 0 No overvoltage condition on the input supply detected by the power monitor. 1 An overvoltage condition on the input supply was detected by the power monitor. 5 VIN_UV_WARN Latched 0 No undervoltage condition on the input supply detected by the power monitor. 1 An undervoltage condition on the input supply was detected by the power monitor. 4 VIN_UV_FAULT Latched 0 No undervoltage detected on the UV pin. 1 An undervoltage was detected on the UV pin. [3:0] Reserved 0000 Always reads as 0000. STATUS_MFR_SPECIFIC Code: 0x80, read byte. Value after reset: 0x00. Table 25. Bit Descriptions for STATUS_MFR_SPECIFIC Command Bits Bit Name Behavior Settings Description 7 FET_HEALTH_BAD Latched 0 FET behavior appears to be as expected. 1 FET behavior suggests that the FET may be shorted. 6 UV_CMP_OUT Live 0 Input voltage to UV pin is above threshold. 1 Input voltage to UV pin is below threshold. 5 OV_CMP_OUT Live 0 Input voltage to OV pin is below threshold. 1 Input voltage to OV pin is above threshold. 4 Reserved 0 Always reads as 0. 3 HS_INLIM Latched 0 The ADM1275 has not actively limited the current into the load. 1 The ADM1275 has actively limited current into the load. This bit differs from the IOUT_OC_FAULT bit in that the HS_INLIM bit is set immediately, whereas the IOUT_OC_FAULT bit is not set unless the time limit set by the capacitor on the TIMER pin elapses. [2:1] HS_SHUTDOWN_CAUSE Latched 00 The ADM1275 is either enabled and working correctly, or has been shut down using the OPERATION command. 01 An IOUT_OC_FAULT condition occurred that caused the ADM1275 to shut down. 10 A VIN_UV_FAULT condition occurred that caused the ADM1275 to shut down. 11 A VIN_OV_FAULT condition occurred that caused the ADM1275 to shut down. 0 IOUT_WARN2 Latched 0 No overcurrent condition on the output supply detected by the power monitor using the IOUT_WARN2_LIMIT command. 1 An undercurrent or overcurrent condition on the output supply was detected by the power monitor using the IOUT_WARN2_LIMIT command. The polarity of the threshold condition is set by the IOUT_WARN2_SELECT bit using the DEVICE_CONFIG command. READ_VIN Code: 0x88, read word. Value after reset: 0x0000. Table 26. Bit Descriptions for READ_VIN Command Bits Bit Name Settings Description [15:12] Reserved 0000 Always reads as 0000. [11:0] VIN Input voltage from the SENSE+ pin measurement, expressed in ADC codes. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |