| 数据搜索系统,热门电子元器件搜索 |
|
ADE7978 数据表(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7978 数据表(HTML) 22 Page - Analog Devices |
|
22 / 120 page ![]() ADE7978/ADE7933/ADE7932 Data Sheet Rev. 0 | Page 22 of 120 Figure 18 through Figure 23 were generated using the following conditions: fundamental voltage component in phase with 5th harmonic; current with a 50 Hz component that has variable amplitudes from 100% of full scale down to 0.033% of full scale and a 5th harmonic with a constant amplitude of 17% of full scale; power factor equal to 1 or 0 on the fundamental and 5th harmonic. Figure 18, Figure 19, Figure 21, and Figure 22 were generated using a voltage with a 50 Hz component that has an amplitude of 50% of full scale and a 5th harmonic with an amplitude of 5% of full scale. Figure 20 and Figure 23 were generated using a voltage with a 50 Hz component that has variable amplitudes from 100% of full scale down to 0.033% of full scale and a 5th harmonic with an amplitude of 5% of full scale. 1.5 –1.5 –1.0 –0.5 0 0.5 1.0 0.01 0.1 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) TA = –40°C TA = +25°C TA = +85°C Figure 18. Fundamental Active Energy Error as a Percentage of Reading over Temperature, PF = 1 1.5 –1.5 –1.0 –0.5 0 0.5 1.0 0.01 0.1 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) VDD = 2.97V VDD = 3.30V VDD = 3.63V Figure 19. Fundamental Active Energy Error as a Percentage of Reading over Power Supply, PF = 1, TA = 25°C 1.5 –1.5 –1.0 –0.5 0 0.5 1.0 0.1 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) TA = –40°C TA = +25°C TA = +85°C Figure 20. Fundamental Current RMS Error as a Percentage of Reading over Temperature, PF = 1 1.5 –1.5 –1.0 –0.5 0 0.5 1.0 0.01 0.1 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) TA = –40°C TA = +25°C TA = +85°C Figure 21. Fundamental Reactive Energy Error as a Percentage of Reading over Temperature, PF = 0 1.5 –1.5 –1.0 –0.5 0 0.5 1.0 0.01 0.1 1 10 100 PERCENTAGE OF FULL-SCALE CURRENT (%) VDD = 2.97V VDD = 3.30V VDD = 3.63V Figure 22. Fundamental Reactive Energy Error as a Percentage of Reading over Power Supply, PF = 0, TA = 25°C 1.5 –1.5 –1.0 –0.5 0 0.5 1.0 0.1 1 10 100 PERCENTAGE OF FULL-SCALE VOLTAGE (%) TA = –40°C TA = +25°C TA = +85°C Figure 23. Fundamental Voltage RMS Error as a Percentage of Reading over Temperature, PF = 1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |