| 数据搜索系统,热门电子元器件搜索 |
|
AS8501 数据表(PDF) 21 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8501 数据表(HTML) 21 Page - ams AG |
|
21 / 41 page ![]() AS8501 - Data Sheet austriamicrosystems Revision 1.1, 04-April-06 www.austriamicrosystems.com Page 20 of 40 7.5.5 ZZR Zener-Zap register (188 bits ) Nr. ZZR bits 183-187 163-182 53-162 0-52 NOTE 0 ZLO ZTR ZCL ZTC1) 2) Notes: 1) 5 bits are reserved for: - 1 bit eventually destroyed during testing, - 2 bits for testing programmed 0 and 1 - 2 bits reserved for locking 2) due to a limited driving capability of the ZZR-cells the maximum reading speed is limited to 500 kHz subregister ZLO: Zener spare bits ( 5 bits ) Nr. Name SYMBOL WORD WIDTH Default Hex 1 Reserved bits ZLO 5 F subregister ZTR: trimming bits (20 bits) Nr. PARAMETER SYMBOL WORD WIDTH Default Dec1) UNIT NOTE 0 TC of reference TRIMBTC 5 0 Bits 1 absolute value of reference TRIMBV 5 0 Bits 2 amplifier offset TRIMA 5 0 Bits 3 current source for external temperature TRIMC 5 0 Bits 4 ∑ trim bits TRIMREG 20 Bits Notes: 1) Default values must be written before start of the test subregister ZCL: calibration bits ( 110 bits ) Nr. PARAMETER SYMBOL WORD WIDTH Default Dec3) UNIT NOTE 0 Calibration G=6, I CGI1 11 1548 Bits 1),4) 1 Calibration G=24, I CGI2 11 1548 Bits 1),4) 2 Calibration G=50, I CGI3 11 1548 Bits 1),4) 3 Calibration G=100, I CGI4 11 1548 Bits 1),4) 4 Calibration U0 CAU0 11 1548 Bits 1),4) 5 Calibration U1 CAU1 11 1548 Bits 1),4) 6 Calibration U2 CAU2 11 1548 Bits 1),4) 7 Calibration U3 CAU3 11 1548 Bits 1),4) 8 Calibration U4 CAU4 11 1548 Bits 1),4) 9 Calibration U5 CAU5 11 1548 Bits 2),4) 10 ∑ cal. Bits ZCL 110 Bits Notes: 1) Decimal default value of the calibration constant for voltage and current is calculated using formula: CGdef=Nmax/NADdef=(Vref*1024)/(Vin*Gmax)=1548 2) Default calibration constant for absolute value of the voltage proportional to absolute temperature is the same as for any other range because it uses the same amplifier and max voltage at max. temperature is approx. 150mV and the gain selected must be g0. 3) Default values must be written before start of the test 4) Calibration constants are selected dependent on state of M1 ( see table below). For M1=1 one of CGI1 to CGI4 is selected according to selected gain of amplifier. For M1=0 the selection of the calibration constants is defined by bits (cu2,cu1,cu0), which are part of CRA and CRB registers and are defined via SDI interface independently of any other selection. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |