| 数据搜索系统,热门电子元器件搜索 |
|
AS8501 数据表(PDF) 28 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8501 数据表(HTML) 28 Page - ams AG |
|
28 / 41 page ![]() AS8501 - Data Sheet austriamicrosystems Revision 1.1, 04-April-06 www.austriamicrosystems.com Page 27 of 40 INTN signal is suppressed. Only after the completion of the reading cycle the ASSP returns to the normal condition and updates the MSR- register immediately if a new AD-conversion has been finished during data transfer. The master unit does not detect any bus conditions since it generates them. Data transfer conditions (direction, register address and register data) must not be changed until the current condition is over. The slave unit does not detect start and exception condition when master-read is in progress. The exception condition is reserved for future use and should be avoided. 8.4 Data transfers Generally the SDI interface is active in all ASSP modes. For security reasons some write operations are restricted to certain modes. Read operations are never disabled in order to keep consistent sdat driving conditions. Writing to the result, trimming and calibration registers (MSR, CAR and TRR) is allowed only in test modes. Writing to the Zener-Zap register is allowed only in mode MZP. The first data bit after the start condition in each data transfer defines the data direction: sdat=high is used for master-read data (mr) condition and sdat=low for master-write data (mw) condition. Data is transferred with the most significant bit (MSB) first. Data bits are composed of register address and register data bits. Register address is transmitted first, followed by the register data bits. The register address is always 4 bits long. The number of register data bits in table 7.5 is implied by the register address. Figure 11: SDI Data transfer The ASSP supports the data transfers presented in Table 8.1. master read-write operations REGISTER ADDRESS Contents read allowed in modes write allowed in modes page OPM 0 operating mode All All CRA 1 measurement set-up A All All CRB 2 measurement set-up B All All CRG 3 general measurement conditions All All MSR 4 measurement result All >7 ZZR 5 Zener-Zap data All 5 CAR 6 calibration register All >7 TRR 7 trimming register All >7 THR 8 alarm or wake-up threshold register All All LSB MSB a0 a1 a2 a3 Register data sclk sdat Register address Direction mw mr |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |