32 / 74 page ![]() Commands STRFNFCA 32/74 Doc ID 023077 Rev 10 Table 21. Idle command description Direction Data Comments Example Host to STRFNFCA 07 Command code Example of switch from Active mode to Hibernate state: >>>0x07 0E 08 04 00 04 00 18 00 00 00 00 00 00 00 00 Example of switch from Active to WFE mode (wake-up by low pulse on IRQ_IN pin): >>>0x07 0E 08 01 00 38 00 18 00 00 60 00 00 00 00 00 Example of switch from Active to WFE mode (wake-up by low pulse on SPI_SS pin): >>>0x07 0E 10 01 00 38 00 18 00 00 60 00 00 00 00 00 Example of switch from Active mode to WFE mode (Sleep / Field Detector with wake-up by Field Detection) : >>> 0x07 0E 04 01 42 38 00 18 00 00 60 00 00 00 00 Example of wake-up by Timeout (7 seconds): Duration before Timeout = 256 * tL * (WU period + 2) * (MaxSleep + 1) >>>0x07 0E 01 21 00 38 00 18 00 60 60 00 00 00 00 08 Example of switch from Active to Tag Detector mode (wake-up by tag detection or low pulse on IRQ_IN pin) (32 kHz, inactivity duration = 272 ms, DAC oscillator = 3 ms, Swing = 63 pulses of 13.56 MHz): >>>0x07 0E 0A 21 00 79 01 18 00 20 60 60 64 74 3F 08 Example of a basic Idle command used during the Tag Detection Calibration process: >>>0x07 0E 03 A1 00 F8 01 18 00 20 60 60 00 xx 3F 01 where xx is the DacDataH value. 0E Length of data <WU Source> Specifies authorized wake- up sources and the LFO frequency EnterCtrlL Settings to enter WFE mode EnterCtrlH WUCtrlL Settings to wake-up from WFE mode WUCtrlH LeaveCtrlL Settings to leave WFE mode (Default value = 0x1800) LeaveCtrlH <WUPeriod> Period of time between two tag detection bursts. Also used to specify the duration before Timeout. <OscStart> Defines the Wait time for HFO to stabilize: <OscStart> * tL (Default value = 0x60) <DacStart> Defines the Wait time for DAC to stabilize: <DacStart> * tL (Default value = 0x60) <DacDataL> Lower compare value for tag detection (1). This value must be set to 0x00 during tag detection calibration. <DacDataH> Higher compare value for tag detection (1). This is a variable used during tag detection calibration. <SwingsCnt> Number of swings HF during tag detection (Default value = 0x3F) <MaxSleep> Max. number of tag detection trials before Timeout (1). This value must be set to 0x01 during tag detection calibration. Also used to specify duration before Timeout. MaxSleep must be: 0x00 < MaxSleep < 0x1F |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |