| 数据搜索系统,热门电子元器件搜索 |
|
AB18X5-RTC 数据表(PDF) 16 Page - Abracon Corporation |
|
|
|||||||||||||||||||||||||||||
AB18X5-RTC 数据表(HTML) 16 Page - Abracon Corporation |
|
16 / 37 page ![]() AB18X5 Real-Time Clock with Power Management Family Date of Issue: October 16, 2014 3.0 x 3.0 mm Page 16 of 37 Abracon Drawing #453568 Revision: C 5.5 VCC Supply Current Table 8 lists the current supplied into the VCC power input under various conditions. For Table 8, TA = -40 °C to 85 °C, VBAT = 0 V to 3.6 V TYP values at 25 °C, MAX values at 85 °C, VCC Power state Table 8: VCC Supply Current SYMBOL PARAMETER TEST CONDITIONS VCC MIN TYP MAX UNIT IVCC:I2C VCC supply current during I2C burst read/write 400kHz bus speed, 2.2k pull-up resistors on SCL/SDA(1) 3.0V 6 10 µA 1.8V 1.5 3 IVCC:SPIW VCC supply current during SPI burst write 2 MHz bus speed (2) 3.0V 8 12 µA 1.8V 4 6 IVCC:SPIR VCC supply current during SPI burst read 2 MHz bus speed (2) 3.0V 23 37 µA 1.8V 13 21 IVCC:XT VCC supply current in XT oscil- lator mode Time keeping mode with XT oscillator running(3) 3.0V 55 330 nA 1.8V 51 290 IVCC:RC VCC supply current in RC oscil- lator mode Time keeping mode with only the RC oscillator running (XT oscillator is off)(3) 3.0V 14 220 nA 1.8V 11 170 IVCC:ACAL Average VCC supply current in Autocalibrated RC oscillator mode Time keeping mode with only RC oscillator running and Auto- calibration enabled. ACP = 512 seconds(3) 3.0V 22 235 nA 1.8V 18 190 IVCC:CK32 Additional VCC supply current with CLKOUT at 32.786 kHz Time keeping mode with XT oscillator running, 32.786 kHz square wave on CLKOUT(4) 3.0V 3.6 8 µA 1.8V 2.2 5 IVCC:CK128 Additional VCC supply current with CLKOUT at 128 Hz All time keeping modes, 128 Hz square wave on CLKOUT(4) 3.0V 7 35 nA 1.8V 2.5 20 (1) Excluding external peripherals and pull-up resistor current. All other inputs (besides SDA and SCL) are at 0V or VCC. AB1805 only. Test conditions: Continuous burst read/write, 0x55 data pattern, 25 s between each data byte, 20 pF load on each bus pin. (2) Excluding external peripheral current. All other inputs (besides SDI, nCE and SCL) are at 0V or VCC. AB1815 only. Test conditions: Continuous burst write, 0x55 data pattern, 25 s between each data byte, 20 pF load on each bus pin. (3) All inputs and outputs are at 0 V or VCC. (4) All inputs and outputs except CLKOUT are at 0 V or VCC. 15 pF capacitive load on CLKOUT. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |