| 数据搜索系统,热门电子元器件搜索 |
|
ADM1034 数据表(PDF) 39 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1034 数据表(HTML) 39 Page - Analog Devices |
|
39 / 40 page ![]() ADM1034 Rev. 0 | Page 39 of 40 Table 72. Register 0x4F, Status 1, Power-On Default = 0x00, Lock = N, SW Reset = Y Bit Name R/W Description 7 Local Temp High R A 1 indicates that the local high limit has been tripped. 6 Local Temp Low R A 1 indicates that the local low limit has been tripped. 5 Remote 1 Temp High R A 1 indicates that the Remote 1 high limit has been tripped. 4 Remote 1 Temp Low R A 1 indicates that the Remote 1 low limit has been tripped. 3 Remote 1 Diode Error R A 1 indicates that a short or an open has been detected on the Remote 1 temperature channel. This test is completed once on each conversion. 2 Remote 2 Temp High R A 1 indicates that the Remote 2 high limit has been tripped. 1 Remote 2 Temp Low R A 1 indicates that the Remote 2 low limit has been tripped. 0 Remote 2 Diode Error R A 1 indicates that a short or an open has been detected on the Remote 2 temperature channel. This test is completed once on each conversion. Table 73. Register 0x50, Status 2, Power-On Default = 0x00, Lock = N, SW Reset = Y Bit Name R/W Description 7 Local THERM R A 1 indicates that the local THERM limit has been tripped. 6 Remote 1 THERM R A 1 indicates that the Remote 1 THERM limit has been tripped. 5 Remote 2 THERM R A 1 indicates that the Remote 2 THERM limit has been tripped. 4 THERM % Exceeded R A 1 indicates that the THERM signal has been asserted for longer than the programmed limit. Clear on Read. If THERM % Limit = 0x00 and THERM is asserted, it is reasserted immediately. 3 THERM Asserted R A 1 indicates that the THERM signal has been asserted low as an input only. 2 THERM_State R A 1 indicates that the THERM pin has been asserted low as an output. 1 Reserved R Reserved. 0 Reserved R Reserved. Table 74. Register 0x51, Status Register 3, Power-On Default = 0x00, Lock = N, SW Reset = Y Bit Name R/W Description 7 Fan 1 Stalled R A 1 indicates that Fan 1 has stalled. 6 Fan Alarm Speed R A 1 indicates that the fans are running at full speed due to an alarm condition, for instance, when a THERM temperature limit is exceeded. 5 Fan 2 Stalled R A 1 indicates that Fan 2 has stalled. 4 Reserved R Reserved. 3 Reserved R Reserved. 2 Reserved R Reserved. 1 Reserved R Reserved. 0 ALERT Low R A 1 indicates that the ADM1034 has pulled the ALERT output pin low. This allows polling of a single status register to determine if an ALERT condition in any of the status registers has occurred. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |