23 / 40 page ![]() ADM1034 Rev. 0 | Page 23 of 40 FAN_FAULT OUTPUT The FAN_FAULT output signals when one or both of the fans stall. Pin 8, the FAN_FAULT output, is a dual-function pin. It defaults to being a FAN_FAULT output but can be reconfigured as an analog input reference for the THERM input. To do this, set the FAN_FAULT/REF (Bit 7) in Configuration Register 4 (Address 0x04) to 1. FAULT QUEUE The ADM1034 has a programmable fault queue option that lets the user program the number of out-of-limit measurements allowable before generating an ALERT. The fault queue affects only temperature measurement channels and is only operational in SMBusALERT mode. It performs some simple filtering, which is particularly useful at the higher conversion rates (16, 32, and 64 conversions/second), where averaging is not carried out. There is a queue for each of the temperature channels. If L (the number programmed to the fault queue) or more consecutive out-of-limit readings are made on the same temperature channel, the fault queue fills, and the SMBusALERT output triggers. To fill the fault queue, one needs L or more consecutive out of limits on the internal temperature channel; L or more consecutive out-of-limits on the external 1 temperature channel; or L or more consecutive out-of-limits on the external 2 temp- erature channel. The fault queue is independent of the state of the bits in the ALERT status registers. Table 22. Fault Queue Address 0x06 Bits <3:0> Fault Queue 000X 1 001X 2 01XX 3 1XXX 4 To reset the fault queue, do one of the following: • SMBus ARA Command • Read Status Register 1 • Power-On Reset The SMBusALERT clears, even if the condition that caused the SMBusALERT remains. The SMBusALERT is reasserted if the fault queue fills up. CONVERSION RATE REGISTER The ADM1034 makes up to 64 measurements per second. However, for the sake of reduced power consumption and better noise immunity, users may run the ADM1034 at a slower conversion rate. Better noise immunity results from the averaging that occurs at the slower conversion rates. Averaging does not occur at rates of 16, 32, or 64 conversions per second. Table 23 lists the available conversion rates. Note that the current round-robin loop must be finished for conversion rates changes to take effect. The conversion rate register is located at Address 0x05. Table 23. Conversion Rates Code Conversion Rate 0x00 0.0625 0x01 0.125 0x02 0.25 0x03 0.5 0x04 1 0x05 2 0x06 4 0x07 8 0x08 16 0x09 32 0x0A 64 0x0B to 0xFF Reserved THERM I/O TIMER AND LIMITS Pin 7 can be configured as either an input or output. As an output it is asserted low to signal that the measured temperature has exceeded preprogrammed temperature limits. The output is automatically pulled high again when the temperature falls below the THERM – Hys limit. The value of hysteresis is programmable in Register 0x1A. THERM is enabled as an output by default on power-up. TEMPERATURE LIMITS TIME THERM, 85 °C THERM THERM-HYST, 80 °C Figure 33. THERM Behavior |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |