| 数据搜索系统,热门电子元器件搜索 |
|
ADM1034 数据表(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1034 数据表(HTML) 18 Page - Analog Devices |
|
18 / 40 page ![]() ADM1034 Rev. 0 | Page 18 of 40 ADDITIONAL FUNCTIONS Several other temperature measurement functions available on the ADM1034 offer the systems designer added flexibility. Turn-off Averaging The ADM1034 performs averaging at conversion rates of less than or equal to 8 conversions per second. This means that the value in the measurement register is the average of 16 measure- ments. For faster measurements, set the conversion rate to 16 conversions per second or greater. (Averaging is not carried out at these conversion rates.) Alternatively, switch off averaging at the slower conversion rates by setting Bit 1 (AVG) of Configuration 1 Register (Address 0x01). Single-Channel ADC Conversions In normal operating mode, the ADM1034 converts on three temperature channels: the local temperature channel, and the remote 1 and remote 2 channels. However, the user has the option to set up the ADM1034 to convert on one channel only. To enable single-channel mode, the user sets the round-robin bit (Bit 7) in Configuration Register 2 (Address 0x02) to 0. When the round-robin bit equals 1, the ADM1034 converts on all three temperature channels. In single-channel mode, it converts on one channel only, to be determined by the state of the channel selector bits (Bits 5 and 4) of the Configuration Register 2 (Address 0x02). Table 11. Channel Selector Bits 5:4 Channel Selector (Configuration 2) 00 Local Channel = Default 01 Remote 1 Channel 10 Remote 2 Channel 11 Reserved Removing Temperature Errors As CPUs run faster and faster, it gets more difficult to avoid high frequency clocks when routing the D+ and D− traces around a system board. Even when the recommended layout guidelines are followed, temperature errors attributed to noise coupled onto the D+ and D− lines remain. High frequency noise generally gives temperature measurements that are consistently too high. The ADM1034 has Local, Remote 1, and Remote 2 temperature offset registers at 0x16, 0x17, and 0x18— one for each channel. By completing a one-time calibration, the user can determine the offset caused by the system board noise and remove it using the offset registers. The registers automatically add a twos compliment word to the remote temperature measurements, ensuring correct readings in the value registers. Table 12. Offset Registers Registration Description Default 0x16 Local Offset 0x00 0x17 Remote 1 Offset 0x00 0x18 Remote 2 Offset 0x00 Table 13. Offset Register Values Code Offset Value 0 0000 000 0°C (Default Value) 0 0000 001 0.125°C 0 0000 111 0.875°C 0 0001 111 1.875°C 0 0111 111 7.875°C 0 1111 111 15.875°C 1 0000 000 −16°C 1 1111 000 −0.875°C |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |