Back Button ADM1034 Datasheet HTML 23Page - Analog Devices ADM1034 Datasheet HTML 24Page - Analog Devices ADM1034 Datasheet HTML 25Page - Analog Devices ADM1034 Datasheet HTML 26Page - Analog Devices ADM1034 Datasheet HTML 27Page - Analog Devices ADM1034 Datasheet HTML 28Page - Analog Devices ADM1034 Datasheet HTML 29Page - Analog Devices ADM1034 Datasheet HTML 30Page - Analog Devices ADM1034 Datasheet HTML 31Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 40 page
background image
ADM1034
Rev. 0 | Page 27 of 40
Figure 40 shows the fan speed measurement period, assuming
that the fan outputs an ideal TACH signal. In reality, the TACH
signal output by the fan is chopped by the drive signal. However,
since the drive and the TACH signal are synchronized, there is
enough information available for the ADM1034 to measure the
fan speed accurately.
CLOCK
IDEAL
TACH
FAN
MEASUREMENT
PERIOD
Figure 40. Fan Speed Measurement for a 4-Pole Fan
FAN SPEED MEASUREMENT REGISTERS
These 16-bit measurements are stored in the TACH value
registers.
Table 25. TACH Value Registers
Register
Description
Default
0x4A
TACH1 Period, LSB
0xFF
0x4B
TACH1 Period, MSB
0xFF
0x4C
TACH2 Period, LSB
0xFF
0x4D
TACH2 Period, MSB
0xFF
READING FAN SPEED
Reading back fan speeds involves a 2-register read for each
measurement. The low byte should be read first. This freezes the
high byte until both high and low byte registers have been read,
preventing erroneous fan speed measurement readings.
The fan tachometer reading registers report back the number of
12.2 µs period clocks (81.92 kHz oscillator) gated to the fan
speed counter, for one full rotation of the fan, assuming the
correct number of poles is programmed. Since the ADM1034
essentially measures the fan TACH period, the higher the count
value, the slower the actual fan speed. A 16-bit fan TACH
reading of 0xFFFF indicates that the fan has stalled or is
running very slowly (< 75 rpm).
CALCULATING FAN SPEED
Fan speed in rpm is calculated as follows. This assumes that the
number of poles programmed in the Configuration Register 3
(Address 0x03) is correct for both fans.
Fan Speed (RPM) = (81920 × 60)/Fan TACH Reading
where:
Fan TACH Reading = 16-bit Fan TACHometer Reading
Example
TACH1 High Byte (Reg. 0x28) = 0x17
TACH1 Low Byte (Reg. 0x29) = 0xFF
What is Fan 1 speed in rpm?
Fan 1 TACH Reading = 0x17FF = 6143d
RPM = (f × 60) / Fan 1 TACH reading
RPM = (81920 × 60) / 6143
Fan Speed = 800 RPM
ALARM SPEED
The fan ALARM speed (Bit 6) in Status Register 3 (Address 0x51)
is set whenever the fan runs at alarm speed. This occurs if the
device is programmed to run the fan at full speed whenever the
THERM temperature limits are exceeded. The device runs at
alarm speed, for example, if the Boost Disable bit (Bit 1) of the
Configuration 2 Register (Address 0x02) is not set to 1.
Fan Response Register
The ADM1034 fan speed controller operates by reading the
current fan speed, comparing it with the programmed fan
speed, and then updating the drive signal applied to the fan. The
rate at which the ADM1034 looks at and updates the drive
signal is determined by the fan response register. Different fans
have different inertias and respond to a changing drive signal
more or less quickly than others. The fan response register
allows the user to tailor the ADM1034 to a particular fan to
prevent situations like overshoot.
The user programs the number of updates the ADM1034 can
make to the drive signal per second. Table 26 lists the available
options.
Table 26. Fan Response Codes
Code
Update Rate
000
1.25 updates/second
001
2.5 updates/second = default
010
5 updates/second
011
10 updates/second
100
20 updates/second
101
40 updates/second
110
80 updates/second
111
160 updates/second
Table 27. Fan Response Register (Address 0x3C)
Bit No.
Function
7
Reserved
<6:4>
Fan 2 Response
3
Reserved
<2:0>
Fan 1 Response



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com