| 数据搜索系统,热门电子元器件搜索 |
|
LTM4656 数据表(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4656 数据表(HTML) 18 Page - Analog Devices |
|
18 / 28 page ![]() LTM4656/LTM4656-1 18 Rev. 0 For more information www.analog.com APPLICATIONS INFORMATION A graphical representation of the aforementioned ther- mal resistances is given in Figure 8; blue resistances are contained within the µModule regulator, whereas green resistances are external to the µModule. As a practical matter, it should be clear to the reader that no individual or sub-group of the four thermal resistance parameters defined by JESD 51-12 or provided in the Pin Configuration section replicates or conveys normal operating conditions of a µModule. For example, in normal board-mounted applications, never does 100% of the device’s total power loss (heat) thermally conduct exclu- sively through the top or exclusively through bottom of the µModule—asthestandarddefinesforθJCtopandθJCbottom, respectively.Inpractice,powerlossisthermallydissipated in both directions away from the package—granted, in the absence of a heat sink and airflow, a majority of the heat flow is into the board. Within a SIP (system-in-package) module, be aware there are multiple power devices and components dissipating power, with a consequence that the thermal resistances relative to different junctions of components or die are not exactly linear with respect to total package power loss. To reconcile this complication without sacrificing modeling simplicity—but also, not ignoring practical realities—an approach has been taken using FEA software modeling along with laboratory testing in a controlled-environment chamber to reasonably define and correlate the thermal resistance values supplied in this data sheet: (1) Initially, FEA software is used to accurately build the mechanical geometry of the µModule and the specified PCB with all of the correct material coefficients along with accurate power loss source definitions; (2) this model simulates a software-defined JEDEC environment consistent with JESD51-9 to predict power loss heat flow and temperature readingsatdifferentinterfacesthatenablethecalculationof theJEDEC-definedthermalresistancevalues;(3)themodel and FEA software is used to evaluate the µModule with heat sink and airflow; (4) having solved for and analyzed these thermal resistance values and simulated various operating conditions in the software model, a thorough laboratory evaluation replicates the simulated conditions with thermocouples within a controlled-environment chamber while operating the device at the same power loss as that which was simulated. An outcome of this process and due-diligence yields a set of derating curves provided in other sections of this data sheet. After these laboratorytestshavebeenperformedandcorrelatedtothe µModulemodel,thentheθJBandθBAaresummedtogether to correlate quite well with the µModule model with no airflow or heat sinking in a properly define chamber. This θJB + θBA value is shown in the Pin Configuration section and should accurately equal the θJA value because ap- proximately 100% of power loss flows from the junction through the board into ambient with no airflow or top mounted heat sink. The 5V, 12V and 24V input power loss curves in Figure 9 toFigure11canbeusedincoordinationwiththeloadcurrent derating curves in Figure 12 to Figure 17 for calculating an approximate θJA thermal resistance for the LTM4656 with various heat sinking and airflow conditions. The power loss curves are taken at room temperature, and are increased with multiplicative factors according to the ambient temperature. These approximate factors is 1.4 assuming the junction temperature at 120°C. The output voltages are chosen to include the lower and higher out- put voltage ranges for correlating the thermal resistance. Thermal models are derived from several temperature measurementsinacontrolledtemperaturechamberalong withthermalmodelinganalysis.Thejunctiontemperatures are monitored while ambient temperature is increased with and without airflow. The power loss increase with ambient temperature change is factored into the derating curves. The junctions are maintained at 120°C maximum while lowering output current or power with increasing ambient temperature. The decreased output current will decrease the internal module loss as ambient temperature isincreased.Themonitoredjunctiontemperatureof120°C minus the ambient operating temperature specifies how much module temperature rise can be allowed. As an example in Figure 15, the load current is derated to ~3.2A at ~ 80°C with no air or heat sink and the power loss for the 12V to 24V at 3.2A output is about 3W. The 4.48W loss is calculated with the ~ 3W room temperature loss from the 12V to 24V power loss curve at 3.2A, and the 1.4 multiplying factor. If the 80°C ambient temperature is subtracted from the 120°C junction temperature, then |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |