18 / 48 page ![]() 18 Am79C02/03/031(A) Data Sheet Master Clock For 2.048 MHz ±100 ppm or 4.096 MHz ±100 ppm operation: Notes: 1. DCLK may be stopped in the High or Low state indefinitely without loss of information. If CS makes a transition to the Low state, the last byte received is interpreted by the Microprocessor Interface logic. 2. The PCM clock (PCLK) frequency must be an integer multiple of the frame sync (FS) frequency and synchronous to the MCLK frequency. The actual PCLK rate is dependent on the number of channels allocated within a frame. The DSLAC supports 2– 128 channels. A PCLK of 1.544 MHz can be used for standard US transmission systems. The minimum clock frequency is 128 kHz. 3. TSC is delayed from FS by a typical value of N • tPCY, where N is the value stored in the time/clock-slot register. 4. There is a special conflict detection circuitry that prevents high-power dissipation from occurring when the DXA or DXB pins of two DSLAC devices are tied together and one DSLAC device starts to transmit before the other has gone into a high- impedance state. 5. The first data bit is enabled on the falling edge of CS or on the falling edge of DCLK, whichever occurs last. 6. tTSO is defined as the time at which the output achieves the open circuit condition. 7. The DSLAC device requires 40 cycles of the 8 MHz internal clock (5 µs) between SIO operations. If the MPI is being accessed while the MCLK input is not active, a Chip Select Off time of 20 µs is required. SWITCHING WAVEFORMS Input and Output Waveforms for AC Tests Master Clock Timing No. Symbol Parameter Min Typ Max Units 35 tMCY Master Clock Period (2.048 MHz) 488.23 488.28 488.33 ns Master Clock Period (4.096 MHz) 244.11 244.14 244.17 36 tMCR Rise Time of Clock 15 37 tMCF Fall Time of Clock 15 38 tMCH MCLK High Pulse Width (2.048 MHz) 200 MCLK High Pulse Width (4.096 MHz) 80 39 tMCL MCLK Low Pulse Width (2.048 MHz) 200 MCLK Low Pulse Width (4.096 MHz) 80 Test Points 2.0 0.8 2.0 0.8 2.4 0.45 09875H-012 09875H-013 35 36 39 38 37 VIH VIL |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |