21 / 98 page ![]() Table 7-3. Converter Control BUCKx_EN / BOOST_EN BUCKx_EN_PIN_C TRL / BOOST_EN_PIN_C TRL EN1 PIN EN2 PIN EN3 PIN BUCKx OUTPUT VOLTAGE / BOOST OUTPUT VOLTAGE Enable or disable control with BUCKx_EN/ BOOST_EN bit 0 Don't Care Don't Care Don't Care Don't Care Disabled 1 00 Don't Care Don't Care Don't Care BUCKx_VSET[7:0] / BOOST_VSET[1:0] Enable or disable control with EN1 pin 1 01 Low Don't Care Don't Care Disabled 1 01 High Don't Care Don't Care BUCKx_VSET[7:0] / BOOST_VSET[1:0] Enable/disable control with EN2 pin 1 10 Don't Care Low Don't Care Disabled 1 10 Don't Care High Don't Care BUCKx_VSET[7:0] / BOOST_VSET[1:0] Enable or disable control with EN3 pin 1 11 Don't Care Don't Care Low Disabled 1 11 Don't Care Don't Care High BUCKx_VSET[7:0] / BOOST_VSET[1:0] Figure 7-4 shows how the BUCKx converter is enabled by an ENx pin or by I2C write access. The soft-start circuit limits the in-rush current during start-up. The output voltage increase rate is typically 30 mV/μsec during soft start. The output voltage becomes slew-rate controlled when the output voltage rises to 0.35-V level. If there is a short circuit at the output and the output voltage does not increase above a 0.35-V level in 1 ms, the converter is disabled, and interrupt is set. When the output voltage rises above the undervoltage power-good threshold level the BUCKx_PG_INT interrupt flag in the INT_BUCK register is set. Power-good thresholds are defined by BUCKx_WINDOW bits. A PGOOD_WINDOW bit in PGOOD_CTRL register sets the detection method for the valid buck output voltage, either undervoltage detection or undervoltage and overvoltage detection. The powergood interrupt flag can be masked using the BUCKx_PGR_MASK bit in the BUCK_MASK register when reaching the valid output voltage. The power- good interrupt flag can also be generated when the output voltage becomes invalid. The interrupt mask for invalid output voltage detection is set by BUCKx_PGF_MASK bit in BUCK_MASK register. When the window monitoring (under and overvoltage monitoring) is selected, the mask bits apply when voltage is crossing either threshold. A BUCKx_PG_STAT bit in BUCK_STAT register shows always the validity of the output voltage; '1' means valid, and '0' means invalid output voltage. www.ti.com LP87702 SNVSBU3 – MARCH 2021 Copyright © 2021 Texas Instruments Incorporated Submit Document Feedback 21 Product Folder Links: LP87702 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |