| 数据搜索系统,热门电子元器件搜索 |
|
ADRF6806ACPZ-R7 数据表(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADRF6806ACPZ-R7 数据表(HTML) 18 Page - Analog Devices |
|
18 / 36 page ![]() ADRF6806 Data Sheet Rev. B | Page 18 of 36 CHARGE PUMP REF PDF PHASE OFFSET POLARITY CP CNTL SRC DB23 DB22 DB21 DB20 DB19 DB18 DB17 DB16 DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 RMS2 RMS1 RMS0 RS1 RS0 CPM CPBD CPB4 CPB3 CPB2 CPB1 CPB0 CPP1 CPP0 CPS CPC1 CPC0 PE1 PE0 PAB1 PAB0 C3(1) C2(0) C1(0) CPC1 CPC0 00 01 10 11 CPS 0 1 CPP1 CPP0 00 01 10 11 CPB4 CPB3 CPB2 CPB1 CPB0 00 000 0 0001 0011 0 010 10 ... ... ... ... ... 111 11 CPBD 0 1 CPM 0 1 RS1 RS0 00 01 10 11 RMS2 RMS1 RMS0 00 0 00 1 01 0 01 1 10 0 10 1 11 0 11 1 10 × 22.5°/ICP, MULT (DEFAULT) ... 31 × 22.5°/ICP, MULT PFD PHASE OFFSET MULTIPLIER 0 × 22.5°/ICP, MULT 1 × 22.5°/ICP, MULT 6 × 22.5°/ICP, MULT (RECOMMENDED) BOTH ON PUMP DOWN PUMP UP TRISTATE (DEFAULT) OUPUT MUX SOURCE INPUT REF PATH SOURCE PFD PHASE OFFSET MULTIPLIER VALUE CHARGE PUMP CURRENT MULTIPLIER CHARGE PUMP CONTROL PFD EDGE SENSITIVITY CONTROL BITS PFD ANTI- BACKLASH DELAY PE0 0 1 REFERENCE PATH EDGE SENSITIVITY FALLING EDGE (RECOMMENDED) RISING EDGE (DEFAULT) PAB1 PAB0 00 01 10 11 PFD ANTIBACKLASH DELAY 0ns (DEFAULT, RECOMMENDED) 0.5ns 0.75ns 0.9ns CHARGE PUMP CONTROL BUFFERED VERSION OF 0.5 × REFERENCE INPUT CHARGE PUMP CONTROL SOURCE CONTROL BASED ON STATE OF DB7/DB8 (CP CONTROL) CONTROL FROM PFD (DEFAULT) OUTPUT MUX SOURCE LOCK DETECT (DEFAULT) VPTAT BUFFERED VERSION OF REFERENCE INPUT PFD PHASE OFFSET POLARITY NEGATIVE POSITIVE (DEFAULT, RECOMMENDED) CHARGE PUMP CURRENT REFERENCE SOURCE INTERNAL (DEFAULT) EXTERNAL 0.25 × REFERENCE INPUT CHARGE PUMP CURRENT MULTIPLIER 1 2 (DEFAULT, RECOMMENDED) 3 4 INPUT REFERENCE PATH SOURCE 2 × REFERENCE INPUT REFERENCE INPUT (DEFAULT) 0.5 × REFERENCE INPUT BUFFERED VERSION OF 2 × REFERENCE INPUT TRISTATE RESERVED (DO NOT USE) PE1 0 1 DIVIDER PATH EDGE SENSITIVITY FALLING EDGE (RECOMMENDED) RISING EDGE (DEFAULT) ... ... ... ... ... ... ... ... ... ... ... ... RESERVED (DO NOT USE) Figure 37. Charge Pump, PFD, and Reference Path Control Register (R4) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |