Back Button AD5372BCPZ Datasheet HTML 17Page - Analog Devices AD5372BCPZ Datasheet HTML 18Page - Analog Devices AD5372BCPZ Datasheet HTML 19Page - Analog Devices AD5372BCPZ Datasheet HTML 20Page - Analog Devices AD5372BCPZ Datasheet HTML 21Page - Analog Devices AD5372BCPZ Datasheet HTML 22Page - Analog Devices AD5372BCPZ Datasheet HTML 23Page - Analog Devices AD5372BCPZ Datasheet HTML 24Page - Analog Devices AD5372BCPZ Datasheet HTML 25Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 22 / 25 page
background image
AD5372/AD5373
Preliminary Technical Data
Rev. P
rF | Page 22 of 25
Table 17. DACs Select by A/B Select Registers
Bits
A/B Select
Register
F7
F6
F5
F4
F3
F2
F1
F0
0
VOUT7
VOUT6
VOUT5
VOUT4
VOUT3
VOUT2
VOUT1
VOUT0
1
VOUT15
VOUT14
VOUT13
VOUT12
VOUT11
VOUT10
VOUT9
VOUT8
2
VOU23
VOUT22
VOUT21
VOUT20
VOUT19
VOUT18
VOUT17
VOUT16
3
VOUT31
VOUT30
VOUT29
VOUT28
VOUT27
VOUT26
VOUT25
VOUT24
POWER SUPPLY DECOUPLING
In any circuit where accuracy is important, careful considera-
tion of the power supply and ground return layout helps to
ensure the rated performance. The printed circuit board on
which the AD5372/AD5373 is mounted should be designed so
that the analog and digital sections are separated and confined
to certain areas of the board. If the AD5372/AD5373 is in a
system where multiple devices require an AGND-to-DGND
connection, the connection should be made at one point only.
The star ground point should be established as close as possible
to the device. For supplies with multiple pins (VSS, VDD, VCC), it
is recommended to tie these pins together and to decouple each
supply once.
The AD5372/AD5373 should have ample supply decoupling of
10 µF in parallel with 0.1 µF on each supply located as close to
the package as possible, ideally right up against the device. The
10 µF capacitors are the tantalum bead type. The 0.1 µF capaci-
tor should have low effective series resistance (ESR) and
effective series inductance (ESI), such as the common ceramic
types that provide a low impedance path to ground at high
frequencies, to handle transient currents due to internal logic
switching.
Digital lines running under the device should be avoided,
because these couple noise onto the device. The analog ground
plane should be allowed to run under the AD5372/AD5373 to
avoid noise coupling. The power supply lines of the
AD5372/AD5373 should use as large a trace as possible to
provide low impedance paths and reduce the effects of glitches
on the power supply line. Fast switching digital signals should
be shielded with digital ground to avoid radiating noise to other
parts of the board, and should never be run near the reference
inputs. It is essential to mini mize noise on all VREF lines.
Avoid crossover of digital and analog signals. Traces on
opposite sides of the board should run at right angles to each
other. This reduces the effects of feedthrough through the
board. A microstrip technique is by far the best, but not always
possible with a double-sided board. In this technique, the
component side of the board is dedicated to ground plane,
while signal traces are placed on the solder side.
As is the case for all thin packages, care must be taken to avoid
flexing the package and to avoid a point load on the surface of
this package during the assembly process.
POWER SUPPLY SEQUENCING
When the supplies are connected to the AD5372/AD5373 it is
important that the AGND and DGND pins are connected to the
relevant ground plane before the positive or negative supplies
are applied. In most applications this is not an issue as the
ground pins for the power supplies will be connected to the
ground pins of the AD5372/AD5373 via ground planes. Where
the AD5372/AD5373 is to be used in a hot-swap card care
should be taken to ensure that the ground pins are connected to
the supply grounds before the positive or negative supplies are
connected. This is required to prevent currents flowing in
directions other than towards an analog or digital ground.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com