| 数据搜索系统,热门电子元器件搜索 |
|
RT9758 数据表(PDF) 40 Page - Richtek Technology Corporation |
|
|
|||||||||||||||||||||||||||||
RT9758 数据表(HTML) 40 Page - Richtek Technology Corporation |
|
40 / 61 page ![]() RT9758 Copyright © 2023 Richtek Technology Corporation. All rights reserved. is a registered trademark of Richtek Technology Corporation. www.richtek.com DS9758-03 May 2023 40 Device Power Up The device is powered by VDDA. When VDDA voltage is higher than VDDA_UVLO Threshold, the device will start working. The VDDA voltage can be powered by either VBUS or VOUT and that is dominated by the higher voltage level. Once the RT9758 is powered, the device will active the address detection mechanism to assign the slave address of device and configuration mode. The slave address of device is determined by voltage level at ADDR pin. The criteria of address detection threshold are shown in electrical characteristics list. After address detection is finished, the host can communicate with the RT9758 by I2C serial interface. Furthermore, the reaction time during VDDA > VDDA_UVLO to I2C release (tWAKE_UP) is around 500 sec. The RT9758 includes a watchdog timer that is enabled by default. When the watchdog timer expired, WDT_STAT and WDT_FLAG turn to high and INT pin is pulsed (tINT_PULL_LOW) 256 sec for interrupt the host. After reset wait time (tWDT_WAIT) 32msec, the related registers are reset to default values. (Refer to Register Descriptions for detail). If the device stays in watchdog timeout status, host can read or write any register to return counting. The Figure 7 shows the device power on flow with protections, insert and indictor function activation list in each state. In order to reduce quiescent current when charge system is unused, the RT9758 is established low quiescent current mode that is called present mode. If EN pin is pulled high or floating, the RT9758 will enter present mode for power save. In present mode, most of sensing circuit inside the RT9758 will be turned off. In other words, all of protection and insert function are inactivated. However, if user desires WRX_OK function active in present mode, user can set WRX_OK_PSM bit and WRX_OK_EN bit both to 1 to active it. If EN pin is pulled low and set CHG_EN bit to 0, this condition is called standby mode. In standby mode, the AP can catch interrupt by INT pin if specific protection or insert is triggered. Before start charging, the AP still can set the register values by I2C protocol in present mode and standby mode. VDDA > VDDA_UVLO Device address detection and I 2 C release EN pin is high or floating Disable Sensing Circuit for Power Save Yes Enable Sensing Circuit Function Activation List : VOUT_INSERT VBUS_INSERT WRX_IN_INSERT VOUT_OVP VBUS_OVP TDIE_OTP VBUS_LOW_ERR WRX_OK WRX_IRE_OCP (if Q0 is turned on) VOUT_PD_EN No CHG_EN = 0 No Yes 4 Operation Mode Present Mode Function Activation List: WRX_IN INSERT (if WRX_O K_PSM bit set to 1) WRX_OK (if WRX_O K_PSM bit an d WRX_O K_EN bit set to 1) VOUT_PD_EN Standby Mode Function Activation List : VOUT_INSERT VBUS_INSERT WRX_IN_INSERT WRX_OK Refer to Table 2. VOUT_PD_EN Figure 7. Device Power On Flow with Protections, Insert and Indicator Function Activation List |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |