| 数据搜索系统,热门电子元器件搜索 |
|
RT9758 数据表(PDF) 41 Page - Richtek Technology Corporation |
|
|
|||||||||||||||||||||||||||||
RT9758 数据表(HTML) 41 Page - Richtek Technology Corporation |
|
41 / 61 page ![]() RT9758 Copyright © 2023 Richtek Technology Corporation. All rights reserved. is a registered trademark of Richtek Technology Corporation. DS9758-03 May 2023 www.richtek.com 41 Protection Feature The RT9758 integrates 9 protections to protect device charging in unexpected condition. These protections are established in bypass mode, reverse bypass mode, DIV2 mode and reverse DIV2 mode. The Table 2 shows the related configuration of 4 operation modes. For example, only just let EN pin pull to high or floating, the RT9758 will operate in present mode for low quiescent current application. If let EN pin pull to GND and set CHG_EN bit to 0, the RT9758 will entry standby mode. And if EN pin pull to GND and set CHG_EN bit to 1, the operation mode is decided by OPERATION_MODE_SELECTION bit and REVERSE_MODE_EN bit setting. About protections that is established in RT9758, the Table 3, Table 4, Table 5 and Table 6 shows the protect function activation list in each mode. In Table 3 , “Stop charge” means the device will stop charge but the CHG_EN bit still keep 1, so the device will soft-start again immediately if VBUS_LOW_ERR status is meet the rule and VBUS is exist. Table 2. Configuration of 4 Operation Modes Mode EN Pin CHG_EN bit OPERATION_MODE_SELECTION bit REVERSE_MODE_EN bit Present H/Floating X X X Standby L 0 X X Bypass L 1 0 0 Reverse Bypass L 1 0 1 DIV2 mode L 1 1 0 Reverse DIV2 L 1 1 1 Table 3. Protection Function Activation List in Bypass Mode Protection Function Protection Method VOUT_OVP (Note 6) 1. Stop charge until fault release over 21m/100msec deglitch time (default) 2. Reset CHG_EN = 0 VBUS_OVP (Note 6) 1. Stop charge until fault release over 21m/100msec deglitch time (default) 2. Reset CHG_EN = 0 IBUS_OCP Stop charge WRX_IRE_OCP Set Q0_CONTROL = 00 (Note 7) VOUT_ERR Hiccup (Note 8) TDIE_OTP Reset CHG_EN = 0 CFLY_DIAG Not active CON_OCP Stop charge VBUS_LOW_ERR Can't do soft-start until VBUS_LOW_ERR = 0 (Note 9) Protection Method depends on AUTO_RECOVERY_EN bit and IN_VALID_RECOVERY_DEGLITCH bit. The WRX_IRE_OCP only active while Q0 is turned on. Hiccup off time depends on VOUT_ERR_OFF_TIME bit. VBUS_LOW_ERR only active before converter soft-start. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |