| 数据搜索系统,热门电子元器件搜索 |
|
ADRF5022BCCZN-R7 数据表(PDF) 4 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADRF5022BCCZN-R7 数据表(HTML) 4 Page - Analog Devices |
|
4 / 12 page ![]() Data Sheet ADRF5022 SPECIFICATIONS analog.com Rev. 0 | 4 of 12 Table 1. Electrical Specifications (Continued) Parameter Symbol Test Conditions/Comments Min Typ Max Unit EN 33 µA RECOMMENDED OPERATING CONDITONS Positive Supply Voltage VDD 3.15 3.45 V Negative Supply Voltage VSS −3.45 −3.15 V Digital Control Input Voltage VCTRL 0 VDD V RF Input Power2, 3 PIN f = 250 MHz to 40 GHz, TCASE = 85°C Through Path RF signal is applied to the RFC or through connected RF1 and RF2 30 dBm Terminated Path RF signal is applied to terminated RF1 and RF2 24 dBm Hot Switching RF signal is applied to the RFC while switching between RF1 and RF2 30 dBm Case Temperature TCASE −40 +105 °C 1 For input linearity performance over frequency, see Figure 14 to Figure 17. 2 For power derating over frequency, see Figure 2 and Figure 3. 3 For 105°C operation, the power handling degrades from the TCASE = 85°C specification by 3 dB. SINGLE-SUPPLY OPERATION VDD = 3.3 V, VSS = 0 V, VCTRL/VEN = 0 V or VDD, TCASE = 25°C, 50 Ω system, unless otherwise noted. Table 2. Single-Supply Operation Specifications Parameter Symbol Test Conditions/Comments Min Typ Max Unit FREQUENCY RANGE f 100 45,000 MHz SWITCHING CHARACTERISTICS Rise Time and Fall Time tRISE, tFALL 10% to 90% of RFOUT 22 ns On Time and Off Time tON, tOFF 50% VCTRL to 90% of RFOUT 65 ns 0.1 dB RF Settling Time 50% VCTRL to 0.1 dB of final RFOUT 90 ns INPUT LINEARITY f = 250 MHz to 40 GHz 0.1 dB Power Compression P0.1dB 17 dBm Input Third-Order Intercept IIP3 Two-tone input power = 0 dBm each tone, Δf = 1 MHz 44 dBm RECOMMENDED OPERATING CONDITONS RF Input Power1, 2 PIN f = 250 MHz to 40 GHz, TCASE = 85°C Through Path RF signal is applied to the RFC or through connected RF1 and RF2 17 dBm Terminated Path RF signal is applied to terminated RF1 and RF2 12 dBm Hot Switching RF signal is applied to the RFC while switching between RF1 and RF2 17 dBm 1 For power derating over frequency, see Figure 2 and Figure 3. 2 For 105°C operation, the power handling degrades from the TCASE = 85°C specification by 3 dB. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |