| 数据搜索系统,热门电子元器件搜索 |
|
162673 数据表(PDF) 4 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
162673 数据表(HTML) 4 Page - Christian Bürkert GmbH & Co. KG |
|
4 / 20 page ![]() Type SE35 + S077 4 | 20 Visit product website 1. General technical data 1.1. About the device The device Type SE35 + S077 is available as a Inline flowmeter or a batch controller in a compact variant. 1.2. All variants The following data are valid for both the Inline flowmeter and the batch controller. Product properties Material Make sure the device materials are compatible with the fluid you are using. Further information can be found in chapter “4.1. Bürkert resistApp” on page 9. Further information on the materials can be found in chapter “4.2. Material specifications” on page 10. Non wetted parts Lid PC Front panel film Polyester Cover PC Housing PC Screw Stainless steel Bayonet system PC Cable gland PA Wetted parts Axis Stainless steel 316L (1.4401) Oval gear Stainless steel 316L (1.4401) Sensor-fitting body Aluminium, stainless steel 316L (1.4401) Cover Aluminium, stainless steel 316L (1.4401) Seal FKM or FEP/PTFE encapsulated Display 15 × 60 mm, 8-digit LCD, alphanumeric,15 segments, 9 mm high Compatibility Any pipe from DN 15…DN 100 which is fitted with Bürkert S077 Inline sensor-fitting. For the selection of the nominal diameter of the Inline sensor-fittings, see data sheet Type S077 . Pipe diameter DN 15…DN 100 Dimensions Further information can be found in chapter “5. Dimensions” on page 11. Measuring principle Oval gear Measuring range • Viscosity > 5 mPa.s: 2…1200 l/min (0.53…320 gpm) • Viscosity < 5 mPa.s: 3…616 l/min (0.78…320 gpm) Performance data Measurement deviation • Teach-in or specific K factor, engraved on the Inline sensor-fitting: ± 0.5 % of the measured value at Teach-In flow rate value • Standard K factor: ± 1 % of the measured value Repeatability ± 0.03 % of the measured value 1.) Electrical data Power source (not supplied) Limited power source according to UL/EN 62368-1 standards or limited energy circuit according to UL/ EN 61010-1 paragraph 9.4 Protection against DC polarity reversal Yes Overvoltage protection Yes Voltage supply cable • Cable with maximum operating temperature greater than 80 °C (176 °F) (90 °C (194 °F) for UL Recognized variant) • Max. 50 m length, shielded |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |