| 数据搜索系统,热门电子元器件搜索 |
|
162673 数据表(PDF) 7 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
162673 数据表(HTML) 7 Page - Christian Bürkert GmbH & Co. KG |
|
7 / 20 page ![]() Type SE35 + S077 7 | 20 Visit product website Environment and installation Ambient temperature Operation and storage: • variant 12…36 V DC: 0…+ 60 °C (+ 32…+ 140 °F) • variant 115/230 V AC: 0…+ 50 °C (+ 32…+ 122 °F) 1.4. Batch controller Note: If the device is mounted in a humid environment or outside, then the maximum voltage allowed is 35 V DC instead of 36 V DC. Electrical data Operating voltage (V+) • 12…36 V DC, max tolerance: - 5 % or + 10 % at 12 V DC, ± 10 % at 36 V DC, filtered and regulated Connection to main supply: permanent, through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply • 115/230 V AC, 50/60 Hz Voltage supply available inside the device: – supplied voltage: 27 V DC regulated – maximum current: 125 mA – integrated protection: 125 mA time delay fuse Current consumption With sensor, without consumption of digital input and pulse output • With relays: – ≤ 100 mA (at 12 V DC) – ≤ 50 mA (at 36 V DC) – ≤ 55 mA (115/230 V AC) • Without relay: – ≤ 70 mA (at 12 V DC) – ≤ 35 mA (at 36 V DC) – ≤ 40 mA (115/230 V AC) Power consumption 115/230 V AC powered measuring device: 3 VA Input • DI (1 to 4) • Switching threshold V on: 5…36 V DC • Switching threshold V off max.: 2 V DC • Min. pulse duration: 100 ms • Input impedance: 9.4 kΩ • Galvanic insulation, protected against polarity reversals and voltage spike Output • Transistors (digital outputs DO1 and DO4): – potential-free – NPN or PNP (wiring dependant) – function: pulse output (by default for DO1), batch state (by default for DO4), configurable and parametrisable – 0…300 Hz – 5…36 V DC, 100 mA max., voltage drop at 100 mA: 2.7 V DC – duty cycle (pulse duration/period): > 0.45 – galvanic insulation, protected against overvoltage, polarity reversals and short-circuits • Relays (digital outputs DO2 and DO3): – 2 relays, normally open, parametrisable (by default: DO2 always configured to control the valve, parametrized of 100 % of the batch quantity and DO3 configured as alarm) – non UL recognized device: 230 V AC/3 A or 40 V DC/3 A (resistive load) – UL recognized device: 30 V AC/42 V peak/3 A or 60 V DC/1 A – max. cutting power of 750 VA (resistive load) Voltage supply cable • External diameter (cable): – 6…12 mm (1 cable per cable gland) or – 4 mm when using a multi-way seal (2 cables per cable gland) • Cross section of wires: 0.75 mm² |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |