| 数据搜索系统,热门电子元器件搜索 |
|
TDF8541TH/N2 数据表(PDF) 17 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDF8541TH/N2 数据表(HTML) 17 Page - NXP Semiconductors |
|
17 / 54 page ![]() TDF8541 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved. Product data sheet Rev. 3 — 13 December 2011 17 of 54 NXP Semiconductors TDF8541 I2C-bus controlled 4 45 W power amplifier [1] DBx[D3] indicates a shorted load; DBx[D1] indicates a short to VP; DBx[D0] indicates a short to ground. When set, D4, D5 have no meaning. If during the start-up diagnostics an engine start occurs, the generated offset to measure the DC load is reduced and the start-up diagnostics cannot be performed correctly. In this case the invalid combination DBx[D4:D5] = 11 is set. The start-up diagnostics information in the I2C-bus bits is combined with the AC load detection allowing the start-up diagnostics information to be read when IB4[D4] = 0. If IB4[D4] = 1, the stored start-up diagnostics information bits cannot be read but they will not lose their value. Remark: the shorted load, and short to VP or ground information from the start-up diagnostics is cleared after an I2C-bus read. This indicates the real situation: when the short is removed, the bits are cleared. The DBx[D5] and DBx[D4] information, generated at start-up, is refreshed after a new start-up diagnostics cycle. 7.5.2 DC offset detection The offset detection can be performed with no input signal (for instance when the DSP is muted after a start-up) or with an input signal. If in I2C-bus mode an I2C-bus read of the output offset is performed, the I2C-bus DBx[D2] latches are set. If the amplifier BTL output voltage is within a window with a threshold of 1.3 V (typical), the DBx[D2] latches are reset and their setting is disabled. If for example, after 1 s another I2C-bus read is performed and the offset bits are still set, the output did not cross the offset threshold during the last 1 second; see Figure 13. This can mean either a frequency below 1 Hz was applied (1 s I2C-bus read interval) or an output offset of more than 1.3 V is present. Table 5. Start-up diagnostics I2C-bus bits DC load bits[1] Meaning DBx[D5] DBx[D4] 0 0 normal load 0 1 line driver mode 1 0 open load 1 1 invalid: overvoltage or undervoltage (VP <10V) has occurred, or start-up diagnostics not completed, or channel has short to VP; indicated in second stage |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |