| 数据搜索系统,热门电子元器件搜索 |
|
TDF8541TH/N2 数据表(PDF) 21 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDF8541TH/N2 数据表(HTML) 21 Page - NXP Semiconductors |
|
21 / 54 page ![]() TDF8541 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved. Product data sheet Rev. 3 — 13 December 2011 21 of 54 NXP Semiconductors TDF8541 I2C-bus controlled 4 45 W power amplifier 7.7 I2C-bus, legacy mode and address select pin Pin ADSEL can select either of two amplifier modes: legacy mode or I2C-bus mode. 7.7.1 Address select (pin ADSEL) The following amplifier functions are selected with pin ADSEL: • Pin ADSEL shorted: (RADSEL < 470 ) legacy mode, no I2C-bus communication is needed. • Resistor connected between pin ADSEL and ground: where different I2C-bus addresses can be selected with resistors. • One I2C-bus address can be selected by either forcing a voltage on pin ADSEL or by connecting a high ohmic resistor between pin ADSEL and VP. To avoid address changes during low supply voltage, the address selected by the value of resistor connected to pin ADSEL is latched at voltages below 6 V. The consequence is, during start-up and after every power-on reset, the supply voltage must be above 6 V otherwise the address is invalid. 7.7.2 Legacy mode (RADSEL < 470 ) The function of pin STB changes from off/operating to off/mute/operating and the amplifier starts immediately when pin STB is put into mute or operating mode. Mute operating is controlled via an internal timer (15 ms) to minimise mute-on plops. When pin STB is switched directly from operating to off, first the hard mute is activated (switching to mute within 400 s) and then the amplifier shuts down. To have a plop-free shut-down, first pin STB should be switched to mute for 50 ms and then switched off. 7.7.3 I2C-bus mode If pin STB is LOW, the total quiescent current is low, and the I2C-bus lines are not loaded. When pin STB is switched HIGH, the TDF8541 enters operating mode and performs a POR which makes pin DIAG LOW. The TDF8541 starts when IB1[D0] = 1. Bit D0 also resets the ‘power on reset occurred’ bit (DB2[D7]) and releases pin DIAG. Soft mute and hard mute can be activated via the I2C-bus. Soft mute can be activated independently for the front (channels 1 and 3) and rear (channels 2 and 4), and mutes the audio in 15 ms. Hard mute activates the mute for all channels at the same time and mutes the audio in 400 s. Unmuting after a hard mute will be a soft unmute of approximately 15 ms. When pin STB is switched to Off mode, and the amplifier has started, first the hard mute is activated and then the amplifier shuts down. It is possible to fully mute the amplifiers within 400 s by making pin STB LOW, for example during an engine start. 7.7.4 I2C-bus diagnostic bits read-out/cleared after read The amplifier’s diagnostic information can be read via the I2C-bus. The I2C-bus bits are set if a failure occurs and are reset by the I2C-bus read command (cleared after read). When the failure is removed, the microcontroller knows the cause of the failure by reading the I2C-bus. The consequence of this procedure is that old information is read during the I2C-bus read. Most real information will be gathered within two consecutive read commands. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |