| 数据搜索系统,热门电子元器件搜索 |
|
LT3074AVPBF 数据表(PDF) 48 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LT3074AVPBF 数据表(HTML) 48 Page - Analog Devices |
|
48 / 62 page ![]() Data Sheet LT3074 analog.com Rev 0. 48 of 62 can be up to a 10ms delay from the time the output voltage hits the limit to the time the fault is reported. Transitionary faults that last for a time period smaller than the ADC conversion time are filtered out and not reported. In response to the VOUT_UV_WARN_LIMIT being exceeded, the device: Sets the NONE_OF_THE_ABOVE bit in STATUS_BYTE register. Sets the VOUT bit in the STATUS_WORD register. Sets the VOUT_UV_WARNING bit in the STATUS_VOUT register. Notifies the host by asserting the ALERT pin. This command has two data bytes and is formatted in the Linear_16u format. IOUT_OC_FAULT_LIMIT The IOUT_OC_FAULT_LIMIT command sets the output current limit in amperes. The current limit programming range is from 1A to 6.4A with a step size of 50mA. Programmed current limit is rounded to the nearest 50mA step. For example, 1.01A is rounded to 1A and 1.04A is rounded to 1.05A. If a current limit value less than 1A is programmed, the data is accepted and stored in the IOUT_OC_FAULT_LIMIT register as received and internally the current limit value is set at 1A. For output current limit values set above 4.5A, the current limit is governed by the backup current limit of the LT3074 device. In the event the output current hits the threshold set by the IOUT_OC_FAULT_LIMIT, the device: Regulates the output current set by the IOUT_OC_FAULT_LIMIT. Sets the IOUT_OC_FAULT bit in the STATUS_BYTE register. Sets the IOUT bit in the STATUS_WORD register. Sets the IOUT_OC_FAULT bit in the STATUS_IOUT register. Notifies the host by asserting the ALERT pin. This command has two data bytes and is formatted in the Linear_5s_11s format. IOUT_OC_FAULT_RESPONSE The IOUT_OC_FAULT_RESPONSE notifies the host of the action of the LT3074 when an overcurrent fault is detected. Table 14. IOUT_OC_FAULT_RESPONSE Command Bit Field Descriptions Bit Access Mode Description 7:6 Read Only Response Value Output Status ‘b00 The LT3074 continues to operate indefinitely while maintaining the output current at a value set by the IOUT_OC_FAULT_LIMIT without regard for the output voltage (known as constant current or brickwall limiting). 5:3 Read Only Not supported since LT3074 never shuts down (bits are hardwired to ‘b000). 2:0 Read Only Not supported since LT3074 never shuts down (bits are hard-wired to ‘b000). In addition to the response mentioned above, the device: Sets the IOUT_OC_FAULT bit in the STATUS_BYTE register. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |