| 数据搜索系统,热门电子元器件搜索 |
|
BMP581 数据表(PDF) 23 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMP581 数据表(HTML) 23 Page - Bosch Sensortec GmbH |
|
23 / 75 page ![]() Bosch Sensortec | BST-BMP581-DS004-11 23 | 75 © Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BMP581-DS004-11 as well as in the event of applications for industrial property rights 0b10: Only Pressure data is stored (P-mode) 0b11: Pressure and temperature data is stored (PT-mode) The operational mode can be controlled via the FIFO_CONFIG.cfg_fifo_mode register: 1’b0: streaming mode 1’b1: stop on full mode The two modes differ in how the FIFO reacts to an overflow. A FIFO overflow occurs if the FIFO is full and a new measurement data is ready to be written to the FIFO. In streaming mode, the FIFO will delete the oldest frame, and write the new frame to the FIFO. As a result, the FIFO contains always the most recent frames.5 In stop-on-full mode, frames once written to the FIFO will not be discarded. Instead, new frames will not be written to the FIFO until there is space again. The FIFO decimation factor (or downsampling) can be adjusted With FIFO_SEL.cfg_fifo_dec_sel. Only every n-th sample will be written to the FIFO, where: ������������=2������������������������������������������������_SEL.cfg_fifo_dec_sel The FIFO threshold can be set by FIFO_CONFIG_fifo_threshold. If the fill level of the FIFO reaches the threshold, the FIFO threshold interrupt may be triggered (see Chapter 3.7.2.1). The meaning of the register field is the following: 0x00: FIFO threshold disablef 0x01..0x1F (or 1..31 decimal): threshold level 0x0F: 15 frames. This is the maximum setting in PT-mode. The most significant bit is ignored. 0x1F: 31 frames. This is the maximum setting in P- or T-mode. 4.6.2 FIFO status The fill level of the FIFO in number of frames can be obtained from FIFO_COUNT.fifo_count. FIFO watermark and FIFO full information can be obtain from the interrupt functionality (see Chapter 3.7.2.1). 4.6.3 FIFO data readout The FIFO can be read out by reading in a burst from register FIFO_DATA. Reads should be performed in the granularity of the frame size (24 or 48 bit) according to the selected frame type. Frames that have been read incompletely will stay in the FIFO memory and will be retransmitted on the next read. The entire FIFO contents can be read in one single burst. If the FIFO is empty, disabled or turns empty during a read, it will return the empty frame, which is 0x7f. Table 10, Table 11 and Table 13 show the frame formats for the three different frame kinds: PT, T and P. The empty frame is shown in Table 13. Table 11: FIFO pressure and temperature frame (PT-fram 2. In order to work properly, streaming mode requires that the clock frequency of host interface is 0.1MHz or above. Otherwise, the FIFO readout bandwidth could be slower than the FIFO write bandwidth, which will cause data loss. 7 6 5 4 3 2 1 0 Temperature temperature XLSB temperature LSB temperature MSB Pressure pressure XLSB press LSB |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |