| 数据搜索系统,热门电子元器件搜索 |
|
CBLUSB01 数据表(PDF) 3 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CBLUSB01 数据表(HTML) 3 Page - Red Lion Controls. Inc |
|
3 / 36 page ![]() 3 general meTer speCifiCaTiOns 1. DISPLAY: 5 digit, 0.56" (14.2 mm) red sunlight readable or standard green LEDs, (-19999 to 99999) 2. POWER: AC Versions: AC Power: 85 to 250 VAC, 50/60 Hz, 15 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. DC Versions (Not available on PAXH): DC Power: 11 to 36 VDC, 11 W (derate operating temperature to 40° C if operating <15 VDC and three plug-in option cards are installed) AC Power: 24 VAC, ± 10%, 50/60 Hz, 15 VA Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working). 3. ANNUNCIATORS: MAX - maximum readout selected MIN - minimum readout selected TOT - totalizer readout selected, flashes when total overflows SP1 - setpoint alarm 1 is active SP2 - setpoint alarm 2 is active SP3 - setpoint alarm 3 is active SP4 - setpoint alarm 4 is active Units Label - optional units label backlight 4. KEYPAD: 3 programmable function keys, 5 keys total 5. A/D CONVERTER: 16 bit resolution 6. UPDATE RATES: A/D conversion rate: 20 readings/sec. Step response: 200 msec. max. to within 99% of final readout value (digital filter and internal zero correction disabled) 700 msec. max. (digital filter disabled, internal zero correction enabled) PAXH Only: 1 sec max. to within 99% of final readout value (digital filter disabled) Display update rate: 1 to 20 updates/sec. Setpoint output on/off delay time: 0 to 3275 sec. Analog output update rate: 0 to 10 sec Max./Min. capture delay time: 0 to 3275 sec. 7. DISPLAY MESSAGES: “OLOL” - Appears when measurement exceeds + signal range. “ULUL” - Appears when measurement exceeds - signal range PAXT: “SHrt” - Appears when shorted sensor is detected. (RTD only) PAXT: “OPEN” - Appears when open sensor is detected. “. . . .” - Appears when display values exceed + display range. “- . . .” - Appears when display values exceed - display range. “E . . .” - Appears when Totalizer exceeds 9 digits. “h . . .” - Denotes the high order display of the Totalizer. 8. INPUT CAPABILITIES: See specific product specifications, pages 4-6 9. EXCITATION POWER: See specific product specifications, pages 4-6 10. LOW FREQUENCY NOISE REJECTION: (Does not apply to PAXH) Normal Mode: > 60 dB @ 50 or 60 Hz ±1%, digital filter off Common Mode: >100 dB, DC to 120 Hz 11. USER INPUTS: Three programmable user inputs Max. Continuous Input: 30 VDC Isolation To Sensor Input Common: Not isolated. (Not PAXH) PAXH: Isolation to Sensor Input Common: 1400 Vrms for 1 min. Working Voltage: 125 V Response Time: 50 msec. max. Logic State: Jumper selectable for sink/source logic INPUT STATE SINKING INPUTS 22 KΩ pull-up to +5 V SOURCING INPUTS 22 KΩ pull-down Active VIN < 0.9 VDC VIN > 3.6 VDC Inactive VIN > 3.6 VDC VIN < 0.9 VDC 12. TOTALIZER: Function: Time Base: second, minute, hour, or day Batch: Can accumulate (gate) input display from a user input Time Accuracy: 0.01% typical Decimal Point: 0 to 0.0000 Scale Factor: 0.001 to 65.000 Low Signal Cut-out: -19,999 to 99,999 Total: 9 digits, display alternates between high order and low order readouts 13. CUSTOM LINEARIZATION: Data Point Pairs: Selectable from 2 to 16 Display Range: -19,999 to 99,999 Decimal Point: 0 to 0.0000 PAXT: Ice Point Compensation: user value (0.00 to 650.00 µV/°C) 14. MEMORY: Nonvolatile E2PROM retains all programmable parameters and display values. 15. ENVIRONMENTAL CONDITIONS: Operating Temperature Range: 0 to 50°C (0 to 45°C with all three plug-in cards installed) Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2 g. Shock According to IEC 68-2-27: Operational 25 g (10 g relay), 11 msec in 3 directions. Storage Temperature Range: -40 to 60°C Operating and Storage Humidity: 0 to 85% max. RH non-condensing Altitude: Up to 2000 meters 16. CERTIFICATIONS AND COMPLIANCES: SAFETY UL Recognized Component, File #E179259, UL61010A-1, CSA C22.2 No. 61010-1 PAXT Only: File # E156876, UL873, CSA C22.2 No. 24 Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc. UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95 LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards Type 4X Enclosure rating (Face only), UL50 IECEE CB Scheme Test Report #04ME11209-20041018 Issued by Underwriters Laboratories, Inc. IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part I IP65 Enclosure rating (Face only), IEC 529 IP20 Enclosure rating (Rear of unit), IEC 529 ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326:2006: Electrical Equipment for Measurement, Control and Laboratory use. Immunity to Industrial Locations: Electrostatic discharge EN 61000-4-2 Criterion A 4 kV contact discharge 8 kV air discharge Electromagnetic RF fields EN 61000-4-3 Criterion A4 10 V/m (80 MHz to 1 GHz) 3 V/m (1.4 GHz to 2 GHz) 1 V/m (2 GHz to 2.7 GHz) Fast transients (burst) EN 61000-4-4 Criterion B 2 kV power 1 kV I/O signal 2 kV I/O signal connected to power Surge EN 61000-4-5 Criterion A power 1 kV L to L, 2 kV L to G signal 1 kV RF conducted interference EN 61000-4-6 Criterion A 3 Vrms Power freq magnetic fields EN 61000-4-8 Criterion A 30 A/m AC power EN 61000-4-11 Voltage dip Criterion A 0% during 1 cycle 40% during 10/12 cycle 70% during 25/30 cycle Short interruptions Criterion C 0% during 250/300 cycles Emissions: Emissions EN 55011 Class A Notes: 1. Criterion A: Normal operation within specified limits. 2. Criterion B: Temporary loss of performance from which the unit self- recovers. 3. Criterion C: Temporary loss of function where system reset occurs. 4. Self-recoverable loss of performance during EMI disturbance at 10 V/m: Measurement input and/or analog output signal may deviate during EMI disturbance. For operation without loss of performance: Unit is mounted in a metal enclosure (Buckeye SM7013-0 or equivalent) I/O and power cables are routed in metal conduit connected to earth ground. Refer to EMC Installation Guidelines section of the bulletin for additional information. 17. CONNECTIONS: High compression cage-clamp terminal block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. 18. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use. IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and mounting clip included. 19. WEIGHT: 10.4 oz. (295 g) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |