27 / 36 page ![]() 27 (CSR) Control Status Register The Control Status Register is used to both directly control the meter’s outputs (setpoints and analog output), and interrogate the state of the setpoint outputs. The register is bit mapped with each bit position within the register assigned to a particular control function. The control function are invoked by writing to each bit position. The bit position definitions are: Although the register is bit mapped starting with bit 7, HEX < > characters are sent in the command string. Bits 7 and 5 always stay a zero, even if a “1” is sent. This allows ASCII characters to be used with terminals that may not have extended character capabilities. Writing a “1” to bit 4 of CSR selects manual mode. In this mode, the setpoint outputs are defined by the values written to the bits b0, b1, b2, b3; and the analog output is defined by the value written to the AOR. Internal control of these outputs is then overridden. In automatic mode, the setpoint outputs can only be reset off. Writing to the setpoint output bits of the CSR has the same effect as a Reset command (R). The contents of the CSR may be read to interrogate the state of the setpoint outputs and to check the status of the temperature sensor (PAXT only). Examples: 1. Set manual mode, turn all setpoints off: V is command write, J is CSR and * is terminator. 2. Turn SP1, SP3 outputs on and SP2, SP4 outputs off: 3. Select Automatic mode: Note: Avoid writing values <0A> (LF), <0D> (CR), <24> ($) and <2E> (*) to the CSR. These values are interpreted by the meter as end of command control codes and will prematurely end the write operation. (AOR) Analog Output Register The Analog Output Register controls the analog output of the meter. The manual mode must first be engaged by setting bit 4 of the Control Status Register. The range of values of this register is 0 to 4095, which corresponds to 0 mA, 0 V and 20 mA, 10 V; respectively. The table lists correspondence of the output signal with the register value. *Due to the absolute accuracy rating and resolution of the output card, the actual output signal may differ 0.15% FS from the table values. The output signal corresponds to the range selected (20 mA or 10 V). Writing to this register while the meter is in the manual mode causes the output signal to update immediately. While in the automatic mode, this register may be written to, but the output will not update until the meter is placed in manual mode. Examples: 1. Set output to full scale: VI4095* 2. Set output to zero scale: VI0* bit 0: Setpoint 1 Output Status 0 = output off 1 = output on bit 1: Setpoint 2 Output Status 0 = output off 1 = output on bit 2: Setpoint 3 Output Status 0 = output off 1 = output on bit 3: Setpoint 4 Output Status 0 = output off 1 = output on bit 4: Manual Mode 0 = automatic mode 1 = manual mode bit 5: Always stays 0, even if 1 is sent. bit 6: Sensor Status (PAXT only) 0 = sensor normal 1 = sensor fail bit 7: Always stays 0, even if 1 is sent. SERIAL COMMANDS FOR PAX SOFTWARE 7 6 5 4 3 2 1 0:bit location VJ<30>* or VJ0* ASCII 0 = 0 0 1 1 0 0 0 0 or <30> VJ<35>* or VJ5* or <35> 1 0 1 0 1 1 0 0 ASCII 5 = 0:bit location 1 2 3 4 5 6 7 VJ<40>* or VJ@* or <40> 0 0 0 0 0 0 1 0 ASCII @ = 0:bit location 1 2 3 4 5 6 7 Command Response Time The meter can only receive data or transmit data at any one time (half-duplex operation). The meter ignores commands while transmitting data, but instead uses RXD as a busy signal. When sending commands and data to the meter, a delay must be imposed before sending another command. This allows enough time for the meter to process the command and prepare for the next command. At the start of the time interval t1, the computer program prints or writes the string to the com port, thus initiating a transmission. During t1, the command characters are under transmission and at the end of this period, the command terminating character (*) is received by the meter. The time duration of t1 is dependent on the number of characters and baud rate of the channel. t1 = (10 * # of characters) / baud rate At the start of time interval t2, the meter starts the interpretation of the command and when complete, performs the command function. This time interval t2 varies from 2 msec to 50 msec. If no response from the meter is expected, the meter is ready to accept another command. If the meter is to reply with data, the time interval t2 is controlled by the use of the command terminating character. The standard command line terminating character is ‘*’. This terminating character results in a response time window of 50 msec minimum and 100 msec maximum. This allows sufficient time for the release of the sending driver on the RS485 bus. Terminating the command line with ‘$’ results in a response time window (t2) of 2 msec minimum and 50 msec maximum. The faster response time of this terminating character requires that sending drivers release within 2 msec after the terminating character is received. At the beginning of time interval t3, the meter responds with the first character of the reply. As with t1, the time duration of t3 is dependent on the number of characters and baud rate of the channel. t3 = (10 * # of characters) / baud rate. At the end of t3, the meter is ready to receive the next command. The maximum serial throughput of the meter is limited to the sum of the times t1, t2 and t3. Ready Ready 1 t t2 Ready t1 t2 Ready t3 Command String Transmission Meter Response Time Command Terminator Received First Character of Reply Reply Transmission NO REPLY FROM METER RESPONSE FROM METER Time Timing Diagram Figure Register Value Output Signal* I (mA) V (V) 0.000 0.000 0 1 0.005 0.0025 5.000 10.000 2047 4094 19.995 9.9975 10.000 20.000 4095 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |