9 / 36 page ![]() 9 PAXP Jumper Selection PAXS Jumper Selection REAR TERMINALS SOURCE SINK USER INPUT LOGIC JUMPER JUMPER SELECTIONS The indicates factory setting. Main Circuit Board USER INPUT JUMPER LOCATION Main Circuit Board JUMPER LOCATION JUMPER LOCATION USER INPUT INPUT RANGE BRIDGE 10V 5V SINK SOURCE ±240mV ±24mV INPUT RANGE USER INPUT BRIDGE EXCITATION REAR TERMINALS JUMPER SELECTIONS The indicates factory setting. Bridge Excitation One jumper is used to select bridge excitation to allow use of the higher sensitivity 24 mV input range. Use the 5 V excitation with high output (3 mV/V) bridges. The 5 V excitation also reduces bridge power compared to 10 V excitation. A maximum of four 350 ohm load cells can be driven by the internal bridge excitation voltage. PAXH Jumper Selection REAR TERMINALS 20 mA 200 µA 2 mA 200 mA INPUT RANGE 20 V .2V/2V 300 V SIGNAL VOLTAGE: OFF CURRENT: ON COUPLE AC: OFF DC: ON SOURCE SINK USER INPUT 2 V ONLY JUMPER SELECTIONS The indicates factory setting. Signal Jumper One jumper is used for the input signal type. For current signals, the jumper is installed. For voltage signals, remove the jumper from the board. (For 2 V inputs, this removed jumper can be used in the “2 V only” location.) Couple Jumper One jumper is used for AC / DC couple. If AC couple is used, then the jumper is removed from the board. If DC couple is used, then the jumper is installed. Input Range Jumper For most inputs, one jumper is used to select the input range. However, for the following ranges, set the jumpers as stated: 5 A: Remove all jumpers from the input range. 2 V: Install one jumper in “.2/2V” position and one jumper in “2 V only”. All Other Ranges: One jumper in the selected range only. Do not have a jumper in both the voltage and current ranges at the same time. Avoid placing a jumper across two ranges. CAUTION: To maintain the electrical safety of the meter, remove unneeded jumpers completely from the meter. Do not move the jumpers to positions other than those specified. Main Circuit Board Jumper Locations CURR/VOLT SIGNAL 2 V ONLY USER INPUT AC/DC COUPLE VOLTAGE CURRENT RANGES |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |