11 / 36 page ![]() 11 WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter. All conductors should conform to the meter’s voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that power supplied to the meter (DC or AC) be protected by a fuse or circuit breaker. When wiring the meter, compare the numbers embossed on the back of the meter case against those shown in wiring drawings for proper wire position. Strip the wire, leaving approximately 0.3" (7.5 mm) bare lead exposed (stranded wires should be tinned with solder). Insert the lead under the correct screw- clamp terminal and tighten until the wire is secure. (Pull wire to verify tightness.) Each terminal can accept up to one #14 AWG (2.55 mm) wire, two #18 AWG (1.02 mm), or four #20 AWG (0.61 mm). EMC INSTALLATION GUIDELINES Although this meter is designed with a high degree of immunity to Electro- Magnetic Interference (EMI), proper installation and wiring methods must be followed to ensure compatibility in each application. The type of the electrical noise, its source or the method of coupling into the unit may be different for various installations.Listed below are some EMC guidelines for successful installation in an industrial environment. 1. The meter should be mounted in a metal enclosure, which is properly connected to protective earth. 2. With use of the lower input ranges or signal sources with high source impedance, the use of shielded cable may be necessary. This helps to guard against stray AC pick-up. Attach the shield to the input common of the meter. Line voltage monitoring and 5A CT applications do not usually require shielding. 3. To minimize potential noise problems, power the meter from the same power branch, or at least the same phase voltage as that of the signal source. 4. Never run Signal or Control cables in the same conduit or raceway with AC power lines, conductors feeding motors, solenoids, SCR controls, and heaters, etc. The cables should be run in metal conduit that is properly grounded. This is especially useful in applications where cable runs are long and portable two-way radios are used in close proximity or if the installation is near a commercial radio transmitter. 5. Signal or Control cables within an enclosure should be routed as far away as possible from contactors, control relays, transformers, and other noisy components. 6. In extremely high EMI environments, the use of external EMI suppression devices, such as ferrite suppression cores, is effective. Install them on Signal and Control cables as close to the unit as possible. Loop the cable through the core several times or use multiple cores on each cable for additional protection. Install line filters on the power input cable to the unit to suppress power line interference. Install them near the power entry point of the enclosure. The following EMI suppression devices (or equivalent) are recommended: Ferrite Suppression Cores for signal and control cables: Fair-Rite # 0443167251 (RLC #FCOR0000) TDK # ZCAT3035-1330A Steward #28B2029-0A0 Line Filters for input power cables: Schaffner # FN610-1/07 (RLC #LFIL0000) Schaffner # FN670-1.8/07 Corcom #1VR3 Note: Reference manufacturer’s instructions when installing a line filter. 7. Long cable runs are more susceptible to EMI pickup than short cable runs. Therefore, keep cable runs as short as possible. 8. Switching of inductive loads produces high EMI. Use of snubbers across inductive loads suppresses EMI. Snubber: RLC#SNUB0000. 4.0 Wiring THe meTer 4.1 POWER WIRING 1 2 AC Power Terminal 1: VAC Terminal 2: VAC 1 2 + - DC Power Terminal 1: +VDC Terminal 2: -VDC Current Signal (self powered) Terminal 4: +ADC Terminal 5: -ADC Voltage Signal (self powered) Terminal 3: +VDC Terminal 5: -VDC Current Signal (2 wire requiring excitation) Terminal 4: -ADC Terminal 6: +ADC Excitation Jumper: 24 V 3 4 5 + - 300VDC MAX. Before connecting signal wires, the Input Range Jumper and Excitation Jumper should be verified for proper position. 4.2 INPUT SIGNAL WIRING Current Signal (3 wire requiring excitation) Terminal 4: +ADC (signal) Terminal 5: -ADC (common) Terminal 6: +Volt supply Excitation Jumper: 24 V Voltage Signal (3 wire requiring excitation) Terminal 3: +VDC (signal) Terminal 5: -VDC (common) Terminal 6: +Volt supply Excitation Jumper: 24 V 4 5 2A DC MAX. Load - + 3 4 5 6 +Vs 3 WIRE TRANSMITTER COMM. Iout Vout 4 5 6 2 WIRE TRANSMITTER - + +24V PAXD INPUT SIGNAL WIRING |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |