35 / 64 page ![]() DocID11531 Rev 9 35/64 STA326 Register description 64 When ECLE is active, it issues a power device power down signal (EAPD) on clock loss detection. EAPD is used to actively power down a connected DDX® power device. This register has to be written to 1 at start-up to enable the DDX® power device for normal operation. Table 43. Auto-EAPD on clock loss enable Bit R/W RST Name Description 5 RW 0 ECLE Auto EAPD on clock loss 0: disabled 1: enabled Table 44. Software power down Bit R/W RST Name Description 6 RW 1 PWDN Software power down: 0: power down mode: initiates a power-down sequence which results in a soft mute of all channels and finally asserts EAPD circa 260 ms later 1: normal operation Table 45. External amplifier power down Bit R/W RST Name Description 7 RW 0 EAPD External amplifier power down: 0: external power stage power down active 1: normal operation Obsolete Product(s) - Obsolete Product(s) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|