6 / 26 page ![]() 5.1 Shifter, Cascade Adder and Rectifier Data from the mac array enters the datapath via a programmable shifter. The shifter is capable of arithmetic right shifts (divides) of up to 8 bits with rounding, and left shifts of up to 8 bits. The size of this shift is controlled by the status bits BCR0[5-1]. The output of the shifter passes into the cascade adder where it is added, along with any rounding generated by the shifter, to either the cascade input bus (BCR0[0] = 0), or a zero value (BCR[0] = 1). If the result of this 22-bit signed addition is greater than 2 21 - 1, (209715110) then the adder will gen- erate a positive overflow. Likewise, if it is less than -2 21, (-209715210) a negative overflow will be gen- erated. In other words, a positive overflow is gen- erated if the result of adding two positive numbers (both MSBs = 0) is negative (resulting MSB = 1). Conversely, a negative overflow is generated if the result of adding two negative numbers (both MSBs = 1) is positive (MSB = 0). Adding two num- bers of different signs cannot cause the adder to overflow. The output of the cascade adder can optionally be full-wave or half wave rectified under the control of BCR0[7,6]. The output of the rectifier passes onto the X bus. Overflows on the X bus are signalled to both the statistics monitor and the data conditioner. 5.2 Statistics Monitor The statistics monitor allows the user to set up watch dogs on the dynamics of the data on the X bus. It cannot affect the data on the X bus. The statistics gathered provide information on the sys- tem behaviour which can be used to ensure correct data scaling and normalisation. The information is also useful in the control of the overall system’s analogue frontend. Hardware/Functions The statistics monitor consists of a 24 bit Min/Max register (MMR), a 24 bit Min/Max Buffer (MMB), a 22 bit Over/UnderShoot Counter (OUC), a 22 bit Over/UnderShoot Buffer (OUB) and a 22 bit twos complement comparator. It can perform one of four functions : • MAX REGISTER : Capture the maximum value of data and store it in the MMR. • MIN REGISTER : Capture the minimum value of data and store it in the MMR. • OVERSHOOT COUNTER : Increment the OUC each time the data value exceeds the preset value in the MMR. • UNDERSHOOT COUNTER : Increment the OUC each time the data value is less than the preset value in the MMR. The mode of operation is determined by the Max/Min switch BCR1[0], and the Static Threshold switch BCR1[1]. Operation Each sample on the X bus is compared against the threshold stored in the MMR. If the unit is configured as an overshoot counter and the data on the X bus exceeds the threshold in the MMR, then the counter (OUC) is incremented. If the data is less than or equal to the threshold, then no action will occur. The OUC is unsigned and will not wrap around. Thus it behaves as a saturating counter with a maximum value of 2 22 - 1, (3FFFFF16, 419430310). If there is a positive over- flow on the X bus, then the counter will increment since the correct X bus value must exceed the threshold. Similarly a negative overflow on the X bus will not increment the counter since the correct X bus value cannot exceed the preset threshold. If the unit is configured as an undershoot counter then the counter will be incremented whenever the sample is less than the preset threshold. In this case a negative overflow will cause the counter to increment. If the unit is configured as a max register and the X bus exceeds the current threshold in the MMR, then the value on the Xbus is loaded into the MMR and becomes the new threshold and the counter is incremented. If the threshold is not exceeded then no action occurs. Thus the value in the MMR is the maximum value that has appeared on the X bus, and the value in the OUC has been incremented by the number of times that the threshold has been updated. If the unit is configured as a min register then the threshold is updated and the counter incremented whenever the X bus is less than the current thresh- old. When operating as a min/max register, overflows on the X bus can never cause the threshold to be updated as this would load an erroneous value into the MMR. IMSA110 6/26 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |