| 数据搜索系统,热门电子元器件搜索 |
|
MPF0900AMMA2ES 数据表(PDF) 102 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF0900AMMA2ES 数据表(HTML) 102 Page - NXP Semiconductors |
|
102 / 205 page ![]() NXP Semiconductors PF09 Nine-channel power management IC with advanced system safety monitoring The VSWx_RUN[7:0] and VSWx_STBY[7:0] bits are designed as secure write bits to ensure that output voltages are not changed by mistake during the SYSTEM ON states. The OTP_SWx_DVS[1:0] bits are used to program the default slew rate for the SW regulator turn-on and turn-off ramps. During the SYSTEM ON states, the DVS range is between 0.65 V and 0.9 V, with an OV/UV threshold of 5 % or wider and a DVS ramp of 3.9 mV/μs or slower. The SYSTEM ON DVS rate is controlled by the SWx_DVS[1:0] bits on the functional registers. SWx_DVS[1:0] Clocking factor SWx ramp-up slope rate[1][2] SWx ramp-down slope rate[1][2] 00 8 1.95 mV/µs 1.95 mV/µs 01 4 3.9 mV/µs 3.9 mV/µs 10 2 7.8 mV/µs 7.8 mV/µs 11 1 15.6 mV/µs 15.6 mV/µs Table 127. SWx ramp-down configuration [1] At 20 MHz high-frequency clock selection [2] The slope rate is calculated as (6.25 [mV] * FREQ [MHz]) / (8 * clocking factor). In applications where the output capacitance is larger than the recommended value, the SWx_SLOWDVS bit provides the option to force the ramp-down slope to the slowest discharge speed, to ensure the output is able to fully discharge before a new turn-on cycle is started. The SWx_SLOWDVS bit is reset to 1 at power-up and the MCU can modify it during the SYSTEM ON states if the system requires a faster discharge on the SWx regulator. SWx_SLOWDVS Ramp-down DVS 0 Same as ramp up 1 1.95 mV/µs Table 128. Ramp-down DVS The SWx regulator is only allowed to request a dynamic voltage change when the default OTP value is set to be within the DVS range (0.3 V to 1.35 V). A voltage configuration outside of the DVS range will be changed to the default OTP value, and any voltage change requested via the I2C communication will be ignored to avoid an invalid configuration. The OTP_SWx_DVSMAX[3:0] bits are provided to define the maximum high-voltage delta allowed during a DVS transition. Maximum high-voltage delta is calculated with respect to the default voltage setting selected by the OTP_VSWx_RUN[7:0] bits, to ensure the system is not able to request a voltage change outside of the selected limits defined for a specific application. OTP_SWx_DVSMAX[3:0] SWx high-voltage delta 0000 0.025 V 0001 0.050 V 0010 0.075 V 0011 0.100 V 0100 0.125 V 0101 0.150 V 0110 0.175 V Table 129. SWx high-voltage delta PF09 All information provided in this document is subject to legal disclaimers. © 2026 NXP B.V. All rights reserved. Product data sheet Rev. 1.3 — 16 December 2025 Document feedback 102 / 205 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |