| 数据搜索系统,热门电子元器件搜索 |
|
MPC7410 数据表(PDF) 14 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC7410 数据表(HTML) 14 Page - Freescale Semiconductor, Inc |
|
14 / 56 page ![]() MPC7410 RISC Microprocessor Hardware Specifications, Rev. 6.1 14 Freescale Semiconductor Electrical and Thermal Characteristics 4.2.1 Clock AC Specifications Table 7 provides the clock AC timing specifications as defined in Figure 3. Figure 3 provides the SYSCLK input timing diagram. Figure 3. SYSCLK Input Timing Diagram Table 7. Clock AC Timing Specifications At recommended operating conditions (see Table 3) Characteristic Symbol Maximum Processor Core Frequency Unit Notes 400 MHz 450 MHz 500 MHz Min Max Min Max Min Max Processor frequency fcore 350 400 350 450 350 500 MHz 1 VCO frequency fVCO 700 800 700 900 700 1000 MHz 1 SYSCLK frequency fSYSCLK 33 133 33 133 33 133 MHz 1 SYSCLK cycle time tSYSCLK 7.5 30 7.5 30 7.5 30 ns — SYSCLK rise and fall time tKR and tKF — 0.5 — 0.5 — 0.5 ns/V 2 SYSCLK duty cycle measured at OVDD/2 tKHKL/tSYSCLK 40 60 40 60 40 60 % 3 SYSCLK jitter — — ±150 — ±150 — ±150 ps 4 Internal PLL-relock time — — 100 — 100 — 100 μs5 Notes: 1. Caution: The SYSCLK frequency and PLL_CFG[0:3] settings must be chosen such that the resulting SYSCLK (bus) frequency, CPU (core) frequency, and PLL (VCO) frequency do not exceed their respective maximum or minimum operating frequencies. Refer to the PLL_CFG[0:3] signal description in Section 8.1, “PLL Configuration,” for valid PLL_CFG[0:3] settings. 2. Rise and fall times measurement are determined by the slew rates of the bus interface, rather than by time. As a result, the 0.5 ns rise/fall time spec of the 1.8- and 2.5-V bus interfaces is equivalent to the 1 ns rise/fall time of the 3.3-V bus interface. Both interfaces required a 2 V/ns slew rate. The slew rate is measured as a 1-V change (from 0.2 to 1.2 V) in 0.5 ns for the 1.8- and 2.5-V bus interfaces, whereas the 3.3-V bus interface required a 2-V change (from 0.4 to 2.4 V) in 1 ns. 3. Timing is guaranteed by design and characterization. 4. This represents total input jitter—short- and long-term combined—and is guaranteed by design. 5. Relock timing is guaranteed by design and characterization. PLL-relock time is the maximum amount of time required for PLL lock after a stable VDD and SYSCLK are reached during the power-on reset sequence. This specification also applies when the PLL has been disabled and subsequently re-enabled during sleep mode. Also note that HRESET must be held asserted for a minimum of 255 bus clocks after the PLL-relock time during the power-on reset sequence. SYSCLK VM VM VM CVIH CVIL VM = Midpoint Voltage (OVDD/2) tSYSCLK tKR tKF tKHKL |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |