| 数据搜索系统,热门电子元器件搜索 |
|
FS201 数据表(PDF) 20 Page - ABB |
|
|
|||||||||||||||||||||||||||||
FS201 数据表(HTML) 20 Page - ABB |
|
20 / 35 page ![]() 20 System pro M compact ® Residual-current-operated circuit breaker F 200 series Description Residual-current protective devices have a balance or, as the case may be, differential current transformer as measuring device that is connected with permanent magnet trip via the secondary winding. Residual-current protective devices cover a.c. fault current and pulsating d.c. fault current and are insensitive to current rushes up to 250 A, selective and short-time delayed tripping types up to 3,000 A). Pulse shape 8/20 according to DIN VDE 0432 Part 2. STOTZ residual-current protective devices are surge-proof and thus insensitive to transient leakage current to earth, as may occur e.g. when switching fluorescent lamps, X-ray apparatus, IT systems and also thyristor control. (The value of the surge strength is indicated in the technical data information regarding the switching variants). Protection through RCD of types AC, A and B according to IEC 755 Selective RCCB F 200S Is installed centrally and operates on a time-selective basis with respect to more sensitive downstream residual-current devices. The result is a high degree of service security, as in the case of a fault, only the circuit affected will be switched off. Due to their surge strength of up to 5,000 A/3,000 A, nuisance tripping of STOTZ main RCCBs caused by remote strike is ruled out. They are therefore the perfect choice for the connection of freezers and agricultural applications (e.g. fans in intensive livestock husbandry) according to DIN VDE 0100 Part 705. Short-time delayed RCCBs F 200 R are RCCBs with high surge strength needed where apparatus causes high leakage currents when switched on or off (e.g. lighting circuits with ballast, long lines). Application To obtain a better level of security in all wiring systems, as well as in supply areas with respect to which codes of practice recommend or require the use of residual-current protective devices. Tasks Protection against electric shock Measures for the protection against electric shock as provided for in DIN VDE 0100 Part 410. These measures are: Protection from indirect touch – as fault protection through disconnection of circuit in the case of excessive touch voltage caused by short circuit to exposed conductive part. Protection from direct touch – as additional protection through disconnection when conductive parts are touched. Dangerous leakage current is switched off within the shortest possible time if the rated residual current of the circuit-breakers is I∆ n 30 mA, in the case of people protector FS 201 I∆ n 10 mA. Protection against fire – protection against fire ignited by electricity if the nominal residual current of the circuit-breaker is I∆ n 300 mA. form of residual current sinusoidal a.c. pulsating d.c. smooth d.c. correct functioning of RCD a.c.- sensitive type AC pulsating current-sensitive type A d.c.-sensitive type B F 200 AC F 200 suddenly applied slowly rising suddenly applied with/without superimosed smooth d.c. of 6 mA slowly rising |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |