24 / 35 page ![]() 24 System pro M compact ® Load capability depending on the feed point bar cross section 10 mm2 16 mm2 max. busbar current IS/phase 63 A 80 A max. current in branch IE/phase 100 A 130 A* * If the device is fed via the device terminal, ensure that - irrespective of the current carrying capacity (I S) of the busbar - the following values are not exceeded: For devices up to and including 40 A I n max. 110 A and for 50/63 A In max. 140 A. Description The newly developed pro M compact cross wiring busbar system includes everything that is needed for secure and economic connections of distribution build-in devices of the series S 200 and F 200. The optimised quick fastener of the S 200 series, F 200 , when used together with the System pro M compact cross wiring busbars, makes removing and inserting devices a quick and easy job, and the cross wiring of other devices remains in place, at that. Busbars are supplied ready-to-use and in standard lengths, time-consuming cutting to length or end caps are no longer required. MCBs and RCCBs of the customary System pro M technology can also be easily cross-wired with the new System pro M compact busbars. Technical data specifications: VDE 0660 Part 500, DIN EN 60439-1: 1994 test surge voltage: (1,2/50) 6,2 kV busbar material: SF-Cu F 24 short-circuit withstand capacity: 25 kA insulating profile material: plastic, temperature resistant 90 °C climatic resistance: constant climate L23/83; 40/92 flame-retardant, self-extinguishing 55/20 according to DIN 50 015 dioxine- and halogene-free humid heat, 28 cycles ( IEC 68 Part 2 - 30) busbar cross section: 10 mm2 insulation coordination: acc. to VDE 0110 Part 1 April 1997 (IEC 664) max. operating voltage: 440 V - overvoltage category: III rated surge voltage: 4 kV - pollution degree: 2 incoming supply incoming supply at the beginning of the within the busbar busbar or centre-fed If the device is centre-fed (see picture to the right), ensure that the combined outgoing currents a1 ...an per branch do not exceed the max. busbar current IS/phase referred to above. Busbars for series S 200, S 200 M, F 200, FS 201 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |