21 / 35 page ![]() 21 System pro M compact ® Residual-current-operated circuit-breakers F 200 series/FS 201 Technical data F 200 F 200 R F 204 S FS 201 short time delayed selective RCBO specifications: DIN VDE 0664 Part 11, EN 61008-2-1 DIN VDE 0664 Part 21 and EN 61009/IEC 61009 No. of poles: 2-pole 2-pole 2-pole 4-pole 4-pole 4-pole 4-pole tripping characteristics: – B and C acc. to DIN VDE 0641 and EN 60898; K acc. to DIN VDE 0660 and EN 60947 rated current I n: 16, 25, 40, 63 A 25, 40, 63 A 25, 40, 63 A 40 A, 63 A 6 to 32 (40) A rated residual current I n: 10, 30, 300 30, 100 30 mA 300 mA 10 mA, 30 mA, 300 mA and 500 mA and 300 mA tripping range at 0.50 ... 1.0 · I n at 0.11 ... 1.4 · I n tripping time at 1 · I n: 300 ms 300 ms 120 … 300 ms 150 ... 500 ms 300 ms at 2 · I n: 50 … 150 ms 60 ... 200 ms at 5 · I n: 40 ms 40 ms 40 ... 150 ms 40 ms at 500 A: 20 … 40 ms 40 ... 150 ms tripping time at 1 · 1,4 I n: 300 ms 300 ms 300 ms 300 ms at 5 · 1,4 I n: 40 ms 40 ms 50 ... 150 ms 40 ms rated switching capacity: – – 6 kA, ϕ 0,7 surge strength (impulse waveshape 8/20): 250 A 3000 A 5000 A 250 A short-circuit withstand capacity: 10.000 A, in connection with an upstream 10.000 A, in connection fuse gL 100 A or the STOTZ selective with an upstream fuse main circuit-breaker S 700-E 100 A gL 100 A or the selective main circuit-breaker S 700-E 100 A rated voltage U n: 2-pole: 230 V ~ 4-pole: 230/400 V ~ 230/400 V ~ 2-pole: 230 V ~ max. operating voltage U Bmax:Un + 10 % operative range of test equipment U T: 100 V ~ to 264 V ~ 100 V ~ to 264 V ~ 100 V ~ to 264 V ~ insulation coordination according to DIN VDE 0110 Part 1 and 2 – overvoltage category: III, disconnector abilities – pollution degree: 2 – surge voltage U imp (1,2/50): 4 kV – power-frequency withstand voltage (50/60 Hz): 2.5 kV frequency: 50/60 Hz 50/60 Hz housing: moulding grey moulding grey operating lever/test button: blue black/blue degree of protection: IP 20; in the distribution board IP 40; in moulded-plastic casing IP 55 (see accessories) dimensions: see dimension drawings connection cross section: 1 to 16 mm2 for finely-stranded to massive conductors 1 to 16 mm2 for I n to 40 A, 1 to 25 mm 2 for I n 63 A service life: > 5.000 switches climatic resistance according to DIN IEC 68 Part 2-30: damp heat: 28 cycl. 55/95 … 100 (°/RH) (RH = rel. humidity) damp heat, cyclic (55 °C/28 cycles) alterning climate: 25/95 - 40/93 (°C/RH) constant climate: 23/83, 40/93, 55/95 … 100 (°C/RH) ambient temperature: T max. + 55 °C T min. – 25 °C vibration resistance according to: DIN VDE 0664 Part 1/10.85 and EN 61008 DIN VDE 0664 Part 2/10.85 and EN 61009 terminals: bi-directional cylinder-lift terminal trip-free mechanism: yes connection: individually or collectively via a busbar supplementary devices: type S2C-S/HR s. pagee 17 in preparation F 200 AC – – |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |