9 / 35 page ![]() 9 System pro M compact ® Tripping characteristics thermal release electromagnetic release acc. to tripping characteristic current: tripping time currents: tripping time and rated current conventional conventional hold trip non-triping c. tripping c. current surges at least at DIN VDE B 6 to 63 A 1.13 · In > 1 h 3 · In > 0.1 s 0641/T 11 1.45 · In < 1 h 5 · In < 0.1 s C 0.5 to 63 A 1.13 · In > 1 h 5 · In > 0.1 s 1.45 · In < 1 h 10 · In < 0.1 s D 0.5 to 63 A 1.13 · In > 1 h 10 · In > 0.1 s 1.45 · In < 1 h 20 · In < 0.1 s DIN VDE 0660/9.82 K 0.5 to 63 A 1.05 · In > 1 h 1.2 · In < 1 h not applicable DIN VDE 0660 1.05 · In > 2 h 8 · In > 0.2 s 8/69 1.2 · In < 2 h 12 · In < 0.2 s Part 1 1.5 · In < 2 min. 6.0 · In > 2 s (T1) DIN VDE 0660/9.82 Z 0.5 to 63 A 1.05 · In > 1 h 1.2 · In < 1 h not applicable DIN VDE 0660 1.05 · In > 2 h 2 · In > 0.2 s 8/69 1.2 · In < 2 h 3 · In < 0.2 s Part 1 1.5 · In < 2 min. 6.0 · In > 2 s (T1) The thermal releases are calibrated to a nominal reference ambient temperature; for Z and K, the value is 20 °C, for B and C = 30 °C. In the case of higher ambient temperatures, the current values fall by ca. 6% for each 10 K temperature rise. as from operating temperature (after I 1 > 1 h or, as applicable, 2 h). The standard DIN VDE 0660/9.69 has expired in 1986, but is still referred to due to its complete statement of the tripping characteristics. The indicated tripping values of electromagnetic tripping devices apply to a frequency range of 16 2/3 ... 60 Hz. In the case of diverging frequencies or direct current, the values change by the factor indicated below Miniature circuit-breakers S 200/S 200 M series alternating current direct current 100 Hz 200 Hz 400 Hz factor ca. 1.1 1.2 1.5 1.5 The thermal release operates independently of voltagest. operating sequence: B and C according to DIN VDE 0641, DIN VDE 0660 Part 101 I CS K and Z according to IEC 947 Short circuit rupturing capacity and back-up series alternating current direct current Max. back-up trip characteristic 1phase 2/3phase 1pole rated current 133 V 230 V 230 V 400 V 60 V ... main 133/230 V 230/400 V fuse circuit-br. A kA/cos ϕ kA/cos ϕ kA/cos ϕ kA/cos ϕ kA/T ms gL S 700 S 200-B 6 63 A 100 A S 200 M-B 10 ... 20 10/0.5 6/0.7 10/0.5 6/0.7 10/4.0 100 A 100 A 25 ... 32 100 A 100 A 40 10/0.5 10/0.5 125 A 100 A 50 ... 63 (S 200 M-B) (S 200 M-B) 160 A 100 A S 200-C 0.5 ... 2 unlimited not required S 200 M-C 3 ... 4 20 A – S 200-D 6 40 A 100 A 8 10/0.5 6/0.7 10/0.5 6/0.7 10/4.0 63 A 100 A 10 ... 20 100 A 100 A 25 ... 32 10/0.5 10/0.5 100 A 100 A 40 ( S 200 M-C) (S 200 M-C) 125 A 100 A 50 ... 63 160 A 100 A S 200-K 0.5 ... 2 unlimited not required 3 20 A – 4 25 A – 6 ... 10 63 A 100 A 16 ... 20 10/0.5 6/0.7 10/0.5 6/0.7 10/4.0 80 A 100 A 25 ... 32 100 A 100 A 40 125 A 100 A 50 ... 63 160 A 100 A S 200-Z 0.5 ... 2 unlimited not required 3 ... 4 20 A – 6 35 A 100 A 8 40 A 100 A 10 ... 16 10/0.5 6/0.7 10/0.5 6/0.7 10/4.0 63 A 100 A 20 ... 25 80 A 100 A 32 ... 40 100 A 100 A 50 ... 63 125 A 100 A In symmetrically earthed direct current circuits, 2-pole devices (two poles connected in series) can be used up to 110 VDC. Any connection is possible, polarity does not need to be taken into account. Back-up protection is necessary only if the solid short-circuit current to be expected at the place of installation may exceed the switching capacity indicated. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |