| 数据搜索系统,热门电子元器件搜索 |
|
FS201 数据表(PDF) 6 Page - ABB |
|
|
|||||||||||||||||||||||||||||
FS201 数据表(HTML) 6 Page - ABB |
|
6 / 35 page ![]() 6 System pro M compact ® Miniature circuit-breakers The offer at a glance Description The MCBs of the S 200/S 200 M series have a cur- rent-limiting effect. They have two different trip releases acting on the contact mechanism 1. the delayed thermal release providing overload protection 2. the electromagnetic instantaneous release with “hammer trip” solenoid providing fault current protection. They offer: b high short-circuit capacity b high selectivity for back-up fuse b In case of short-circuit, low stress on the cable in the point of fault due to the high limitation of the let-through ƒi2dt (current heating value). Task To protect against excessive temperature rises of electric items in the case of overcurrents caused by overload, short circuit of earth-fault current if assi- gned according to DIN VDE 0100 Part 430. Protec- tion against electric shock in the case of excessive touch voltage caused by insulation fault if assigned according to DIN VDE 0100 Part 410. Trip charcteristics B C IK · 2 = peak value of prospective short circuit current iD = max. let-through current of device S 200/S 200 M Un = system voltage UB = arc voltage of MCB tK = breaking time of MCB Oscillogram of rupturing process Trip charcteristics and rated current Independent of the type of characteristic, national codes of practice provide what highest rated current and/or performance characteristic can be assigned to the conductor cross section to be protected (e.g. DIN VDE 0100 Part 430). The following assignment rules apply: Ib In Iz; I2 1,45 · Iz Ib = operating current of the circuit to be expected In = rated current of the MCB of characteristics type B, C, D, K and Z Iz = permissible current loading of lines I2 = conventional tripping current B-, C- and D-type trip characteristics for line protection Tripping behaviour according to DIN VDE 0641 Part 11. Rated current 6 ... 63 A, (C 0,5 ... 63 A). The introduction of these trip characteristics enables direct assignments of MCBs to the permissible load of lines I z according to DIN VDE 0298 Part 4/11.98, as the second condition is already fulfilled (I2 = 1.45 · In). K-type trip characteristics Tripping behaviour according to DIN VDE 0660 Part 101 and IEC 947-2, rated current 0.5 ... 63 A, for circuits where current-consuming appartus cause functional current peaks and for the overcurrent protection of lines. Z-type trip characteristics Tripping behaviour according to DIN VDE 0660 Part 101 and IEC 947-2 Rated current 0.5 ... 63 A in 17 grades. For the protection of semiconductors and measuring circuits with transformers. K Z |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |