| 数据搜索系统,热门电子元器件搜索 |
|
TDA7590 数据表(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TDA7590 数据表(HTML) 13 Page - STMicroelectronics |
|
13 / 40 page ![]() TDA7590 Key parameters 13/40 3.1.1 CODEC (ADC/DAC) Test Description Reported typical values (table 3. - ADC and DAC sections) have been measured at Lab level during product evaluation phase. General definitions and procedures are separately defined in following dedicated paragraphs. Total Harmonic Distortion with Noise to Signal (THD+N)/S THD+N is defined as the ratio of the total power of the second power and higher harmonic with noise components to the power of the fundamental for that signal. For THD+N measurement, choose the DSP analyzer in Digital analyzer with THD ratio as measurement option. Measure the THD+N value at -3dB amplitude of the input signal. First measure the THD+N value at 1Vrms which is 0dB reference and then measure the value at -3dB reference. Dynamic Range (DR) DR is defined as the level of THD+N measured when the input sine wave amplitude is so small that no harmonics apart from the fundamental tone are present in the output signal. This way THD+N becomes practically the ratio between the whole signal and noise floor, being a different way to express SNR. As a convention, at which no harmonics should be present in the output signal, it is fixed at -40dB of the full scale amplitude. Crosstalk or Interchannel Isolation A disturbance, caused by electromagnetic interference, along a circuit or a cable pair. An electric signal disrupts another signal in an adjacent circuit and can cause it to become confused and cross over each other. Crosstalk is measured by applying a signal -3dB amplitude of input signal at one channel (A) and no signal at an other channel (B), measuring the effect on this channel(B) because of the channel (A). Total Harmonic Distortion to Signal (THD)/S THD is defined as the ratio of the sum of only those components of the output signal which are harmonic of system input, after having removed the fundamental tone corresponding to the pure sine wave as input and the input signal.This measurement is done by using the Harmonic analyzer which can isolate up to 15th harmonic components on the acquired signal and report the sum of all of them, centering the fundamental tone on the frequency provided by the input signalgenerator. These measurements are performed at -3dB reference amplitude of input signal. DR Dynamic Range 89 dB ICL Interchannel Isolation -100 dB DAC Differential Vpp Maximum Input Range at ADC1 2.8 V THD/S Total Harmonics Distortion to Signal -58 dB (THD+N)/S (THD + Noise) to Signal -57 dB DR Dynamic Range 90 dB ICL Interchannel Isolation -85 dB Table 3. Key parameters (continued) Symbol Parameter Min. Typ. Max. Unit |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |