| 数据搜索系统,热门电子元器件搜索 |
|
AD9520-3/PCBZ 数据表(PDF) 43 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9520-3/PCBZ 数据表(HTML) 43 Page - Analog Devices |
|
43 / 84 page ![]() AD9520-3 Rev. 0 | Page 43 of 84 DIVIDE BY 1, 2, 3, 4, 5, OR 6 LF CLK/CLK R DIVIDER R DELAY N DIVIDER N DELAY PFD CP LOOP FILTER MUX1 REG 0x01E[1] = 1 0 1 REFIN/ REFIN REG 0x01E[0] ZERO DELAY INTERNAL FEEDBACK PATH EXTERNAL FEEDBACK PATH ZERO DELAY FEEDBACK CLOCK CHANNEL DIVIDER 0 CHANNEL DIVIDER 1 CHANNEL DIVIDER 2 CHANNEL DIVIDER 3 OUT0 TO OUT2 OUT3 TO OUT5 OUT6 TO OUT8 OUT9 TO OUT11 AD9520 Figure 48. Zero Delay Function ZERO DELAY OPERATION Zero delay operation aligns the phase of the output clocks with the phase of the external PLL reference input. There are two zero delay modes on the AD9520: internal and external. Internal Zero Delay Mode The internal zero delay function of the AD9520 is achieved by feeding the output of Channel Divider 0 back to the PLL N divider. In Figure 48, the change in signal routing for internal zero delay mode is shown in blue. Internal zero delay mode is selected by setting Register 0x01E[2:1] = 01b. In the default internal zero delay mode, the output of Channel Divider 0 is routed back to the PLL (N divider) through Mux3 and Mux1 (feedback path shown in blue in Figure 48). The PLL synchronizes the phase/edge of the output of Channel Divider 0 with the phase/edge of the reference input. The user can also specify Channel Divider 1, Channel Divider 2, or Channel Divider 3 for zero delay feedback by changing the value in Register 0x01E[4:3]. Because the channel dividers are synchronized to each other, the outputs of the channel divider are synchronous with the reference input. Both the R delay and the N delay inside the PLL can be programmed to compensate for the propagation delay from the output drivers and PLL components to minimize the phase offset between the clock output and the reference input to achieve zero delay. External Zero Delay Mode The external zero delay function of the AD9520 is achieved by feeding one clock output back to the CLK input and ultimately back to the PLL N divider. In Figure 48, the change in signal routing for external zero delay mode is shown in red. External zero delay mode is selected by setting 0x01E[2:1] = 11. In external zero delay mode, one of the twelve output clocks (OUT0 to OUT11) can be routed back to the PLL (N divider) through the CLK/CLK pins and through Mux3 and Mux1. This feedback path is shown in red in . Figure 48 The PLL synchronizes the phase/edge of the feedback output clock with the phase/edge of the reference input. Because the channel dividers are synchronized to each other, the clock outputs are synchronous with the reference input. Both the R delay and the N delay inside the PLL can be programmed to compensate for the propagation delay from the PLL components to minimize the phase offset between the feedback clock and the reference input. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |