| 数据搜索系统,热门电子元器件搜索 |
|
MPR083 数据表(PDF) 13 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPR083 数据表(HTML) 13 Page - Freescale Semiconductor, Inc |
|
13 / 35 page ![]() MPR083 Sensors Freescale Semiconductor 13 Preliminary 4.3 Run1 Mode When in Run1 mode the sensor controller will run continuously. During Run1 all the modules are synchronized by the Master Tick Period. This value can be set by using the Master Tick Period Register as outlined in the following section. While in this mode all functionality of the MPR083 is enabled; touch detection will occur, and I2C communication will be available. This mode is enabled by setting the Configuration Register’s RUNE and DCE bits high. 4.3.1 Master Tick Period Register The Master Tick Period Register is used to set the master tick of this system. All parts of the system are synchronized to this counter. This register is overridden in all modes except for Run1. When not in Run1 mode, the value of this register is ignored and 8ms is used for the primary clock. The I2C slave address of the Master Tick Period Register is 0x05. Figure 16. Master Tick Period Register 4.4 Run2 Mode When in Run2 mode the sensor controller will continue to scan the electrodes but a low power state will be enabled between each cycle. Because of this, any I2C communication that occurs, may or may not respond while the sensor is in this mode. If DCE is enabled the sensor controller transitions between low power and active states. During the active part of the cycle communication with the sensor controller is possible; however, Freescale always requires users to issue an ATTN signal prior to initiating communications. Accessing the I2C interface while DCE mode is enabled without sending an ATTN signal first is likely to produce invalid data. This mode is enabled by setting the Configuration Register’s RUNE bit high and DCE bit low. The only way to exit this mode is to toggle the Attention Pin, refer to Section 4.7. 4.5 Stop1 Mode When in Stop1 mode the sensor controller will not scan the electrodes. While capacitance sensing is disabled I2C communications will still be accepted and the sensor controller will maintain instantaneous response to all register requests. This is the only mode in which register values can be set. This mode is enabled by setting the Configuration Register’s RUNE bit low and DCE bit high. 4.6 Stop2 Mode When in Stop2 mode the sensor controller will not scan the electrodes or accept I2C communication. The MPR083 is off during this mode. This mode is enabled by setting the Configuration Register’s RUNE bit low and DCE bit low. The only way to exit this mode is to toggle the Attention Pin, refer to Section 4.7. 7 6 543210 R MTP W Reset: 0 0 000101 = Unimplemented Table 9. Master Tick Period Register Field Descriptions Field Description 7:0 MTP Master Tick Period – The Master Tick Period selects or reports the current value of the touch sensor controller’s primary clock multiplier. The resulting period must be in the range 5ms to 31ms. If the value is outside of this range the MTP will be set to 00011010. 00000000 Encoding 0 – Sets the primary clock multiplier to 5 ~ 00011010 Encoding 26 - Sets the primary clock multiplier to 31 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |