15 / 35 page ![]() MPR083 Sensors Freescale Semiconductor 15 Preliminary 5 Low Power Configuration 5.1 Introduction The MPR083 features a Low Power mode that can reduce the power consumption into the microamps range. This feature can be used to both adjust the response time of the system, and change the conditions on which Low Power would be enabled. 5.2 Operation This Low Power configuration is only active when the sensor controller is in Run2 mode. The Low Power mode decreases current consumption by increasing the response time of the MPR083. This increase is controlled through two factors. During normal Run2 operation of the sensor controller the Max Response Time (MRT) is calculated by taking the product of the TASP and the primary clock. From Chapter 4 the primary clock is the (MTP + 5) ms. Since the sensor controller is in Run2, the primary clock is also multiplied by a factor of 8. The debounce rate of the MPR083 is 4 times the sample rate thus the MRT is represented by the following equation. Equation 1 First, the Idle Interface Timeout (IIT) represents the total time the touch interface should remain idle before going into Low Power mode. This value can be calculated by taking the product of the ITP, TASP and primary clock (8ms) with a factor of 64. Thus the IIT is represented as follows: Equation 2 Second, the Max Response Time (MRT) represents the total time the touch interface should remain inactive before scanning the electrodes. This value can be calculated by taking the product of the SCD, TASP and primary clock (8ms) with a factor of 5. Thus the MRT is represented as follows: Equation 3 When in Run2 mode, the sensor controller will initially scan the electrodes at the rate of MRT1. When scanning at MRT1 and the touch interface remains idle for the IIT period then the scan period will change to MRT2. When scanning at MRT2 and a touch is detected the scan rate will transition back to MRT1. Figure 18. Low Power Scan Period Transition Diagram MRT1 MTP 5 + 8 ---------------------- 1 + ⎝⎠ ⎛⎞ TASP 48ms × × × = MRT2 MTP 5 + 8 ---------------------- 1 + ⎝⎠ ⎛⎞ TASP SCD 48 × ms × × × = ITT MTP 5 + 8 ---------------------- 1 + ⎝⎠ ⎛⎞ TASP ITP × × 68ms × × = LP DISABLED ITT PERIOD run2 SET TOUCH DETECTED MRT1 MRT2 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |