45 / 155 page ![]() AT697F ADVANCE INFORMATION 45 7703C–AERO–6/09 If a tag parity error is detected during a cache access, a cache miss is generated. The tag and the data are automatically updated. All valid bits except the one corresponding to the newly loaded data are cleared. Each error is reported in the instruction cache tag error counter from the CCR. The instruction cache tag error counter CCR ITE is incremented after each instruc- tion cache tag error detection. If a data sub-block parity error occurs, a miss is also generated but only the failed sub-block is updated with data from main memory. Each error is reported in the instruction cache data error counter from the CCR. The instruction cache data error counter CCR IDE is incremented after each instruction cache data error detection. Data Cache Overview The AT697F data cache is a multi-set cache of 16 kbyte divided in 2 memory sets. Multi-set- cache use improves speed performance. The data cache is divided into cache lines with 16 bytes of data. Each line has a cache tag associated with it consisting of a tag field and one valid bit per 4-byte sub-block. Cache Control The instruction cache operations are controled with the cache control register (CCR). Operation Write The write policy for stores is write-through with no-allocate on write-miss. The write buffer (WRB) consists of three 32-bit registers used to temporarily hold store data until it is sent to the destina- tion device. For half-word or byte stores, the stored data replicated into proper byte alignment for writing to a word-addressed device, before being loaded into one of the WRB registers. The WRB is emptied prior to a load-miss cache-fill sequence to avoid any stale data from being read in to the data cache. Read On a data cache read-miss to a cachable location, 4 bytes of data are loaded into the cache from main memory. Cache Flush Data cache can be flushed by executing the FLUSH instruction, setting logical one in CCR FD in the cache control register, or writing any location with ASI=0x6. The flush operation takes one cycle per line during which the IU will is not halted, but during which the cache is disabled. When the flush operation is completed, the cache will resume the state indicated in the cache control register. Error Reporting Since the processor executes in parallel with the write buffer, a write error will not cause an exception to the store instruction. Depending on memory and cache activity, the write transac- tion may not occur until several clock cycles after the store instructions has completed. If a write error occurs, the currently executing instruction will take trap 0x2B. Note: the 0x2B trap handler should flush the data cache, since a write hit would update the cache while the memory would keep the old value due the write error. If a memory access error occurs during a data load, the corresponding valid bit in the cache tag will not be set. and a data access error trap (tt=0x09) is generated. Data Cache Parity Error detection of cache tags and data is implemented using two parity bits per tag and per 4- byte data sub-block. The tag parity is generated from the tag value and the valid bits. The data parity is derived from the sub-block data. The parity bits are written simultaneously with the associated tag or sub-block and checked on each access. The two parity bits correspond to the parity of odd and even data (tag) bits. If a tag parity error is detected during a cache access, a cache miss is generated. The tag and the data are automatically updated. All valid bits except the one corresponding to the newly loaded data are cleared. Each error is reported in the instruction cache tag error counter from the CCR. CCR DTE is incremented after each data cache tag error detection. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |