10 / 44 page ![]() Obsolete Product(s) - Obsolete Product(s) Functional description STE12PS 10/44 classify the channel and afterwards to issue the power on command. The STE12PS controller can also automatically disconnect a channel in fault condition (if not enabled, the STE12PS will notify automatically only a short circuit condition or an AC disconnection event. Overload or DC disconnection is responsibility of the host controller.) The host controller can also power on a channel skipping detection and/or classification procedures. ● POWER DOWN: the controller is put in power down state. No actions are performed until the power down mode is removed. For all operating modes, except power-down and stand-by, the power ON/OFF condition of each channel can also be managed, directly, by the host processor or controller via a dedicated command. Moreover, the power removal procedure is performed automatically (also in MANUAL mode) when a fault event has been detected (AC/DC disconnection, overload or overcurrent); this behavior can be changed configuring appropriately some dedicated enable/disable bits of channels event registers. With Priority Management in AUTO mode and Smart-power management enabled, it is also possible to set different priorities for different channels. The STE12PS will probe channels starting from those with the highest priority . In case of a shortage of available power, it is also possible to disable powering of newly detected, lower priority ports until the highest detected ones are served. 3.2 Detection and classification 3.2.1 Detection The STE12PS looks for, in turn on the free available ports (according to the priority list if enabled ), for a valid PD signature (25k Ω slope characteristic) by driving two different voltage levels at the port (4V and 8V), and calculating the slope resistance/ conductance by monitoring the current difference . The equivalent circuit for the IEEE802.3af detection phase is shown in Figure 3 below. Figure 3. IEEE802.3af detection circuit As detection is performed by multiplexing a common voltage generator. If more than one port is connected to several PDs, an extra delay in the detection start will be introduced. See Table 12: Electrical characteristics, parameter Tdetd. + D2 P+ P- Zsource V _ + D2 P+ P- Zsource V D1 D2 P+ P- Zsource V _ PC00103 D1(one per port) is external. D2 (one per port) external is required only if the AC_Disconnection function is used, otherwise it is internally emulated. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |